Emerson Rosemount 3051S Series Reference Manual page 134

Scalable pressure, flow, and level solution with hart protocol
Hide thumbs Also See for Rosemount 3051S Series:
Table of Contents

Advertisement

Advanced HART Diagnostic Suite
October 2018
Figure 7-20. Diagnostic Log
Figure 7-20
Status Event
This is the name of the event that was recorded in the transmitter.
status events that can be recorded.
Table 7-9. Possible Status Events for Diagnostic Log
Alert/status
CPU Error Set, Cleared
Electronics Failure Set, Cleared
Field Device Malfunction Set, Cleared
HW/SW Incompatibility Set, Cleared
mA Output Diagnostic Alert Set, Cleared
NV Error Set, Cleared
Pressure Not Updating Set, Cleared
RAM Error Set, Cleared
ROM Error Set, Cleared
Sensor Failure Set, Cleared
Stack Overflow Set, Cleared
SW Flow Control Error Set, Cleared
Transmitter Power Consumption Alert Set, Cleared
124
shows the Diagnostic Log screen where a set of ten events and time stamp can be seen.
Reference Manual
00809-0100-4801, Rev HA
Table 7-9
shows a list of possible
Criticality
Failed
Failed
Failed
Failed
Failed
Failed
Failed
Failed
Failed
Failed
Failed
Failed
Failed
Advanced HART Diagnostic Suite