Aa9Nts - ICP DAS USA I-7021 User Manual

I-7000/7022/7024 series, m-7022/7024/7028 series
Table of Contents

Advertisement

I-7022
M-7022, M-7024U, M-7028

2.24 $AA9NTS

Description:
Sets the analog output configuration of a specified channel.
Syntax:
$AA9NTS[CHKSUM](CR)
$
Delimiter character
AA
Address of the module to be set (00 to FF)
9
Command to set the analog output configuration
N
The channel to be set, zero based
T
Analog output type, see Section 1.11 for details.
S
Analog output slew rate, see Section 1.11 for
details.
Response:
Valid command:
Invalid command: ?AA[CHKSUM](CR)
!
Delimiter character for a valid command
?
Delimiter character for an invalid command
AA
Address of the responding module (00 to FF)
There will be no response if the command syntax is
incorrect, there is a communication error, or there is no
module with the specified address.
102
I-7021/22/24, M-7022/24/28 User Manual, Rev: B2.3
!AA[CHKSUM](CR)