Index
Sub Index
1014h
0
1015h
0
1017h
0
0
1
1018h
2
3
4
0
1200h
1
2
0
RX PDO1 comms param. no. of entries
1400h
1
2
0
RX PDO2 comms param. no. of entries
1401h
1
2
0
1
1600h
2
3
4
0
1
1601h
2
3
4
0
TX PDO1 comms parameter number of entries
1
1800h
2
3
0
1
1801h
2
3
0
1
2
1A00h
3
4
0
1
1A01h
2
3
www.invertekdrives.com
Function
COB-ID EMCY
Inhibit Time Emergency (100μs)
Producer Heartbeat Time (1ms)
Identity Object No. Of entries
Vendor ID
Product Code
Revision Number
Serial Number
SDO Parameter No. Of entries
COB-ID Client -> Server (RX)
COB-ID Server -> Client (TX)
RX PDO1 COB-ID
RX PDO transmission type
RX PDO2 COB-ID
RX PDO2 transmission type
RX PDO1 1 mapping / no. of entries
RX PDO1 1st mapped object
RX PDO1 2nd mapped object
RX PDO1 3rd mapped object
RX PDO1 4th mapped object
RX PDO2 1 mapping / no. of entries
RX PDO2 1st mapped object
RX PDO2 2nd mapped object
RX PDO2 3rd mapped object
RX PDO2 4th mapped object
TX PDO1 COB-ID
TX PDO1 transmission type
TX PDO1 Inhibit time (100μs)
TX PDO2 comms param no. of entries
TX PDO2 COB-ID
TX PDO2 transmission type
TX PDO2 Inhibit time (100μs)
TX PDO1 mapping / no. of entries
TX PDO1 1st mapped object
TX PDO1 2nd mapped object
TX PDO1 3rd mapped object
TX PDO1 4th mapped object
TX PDO2 mapping / no. of entries
TX PDO2 1st mapped object
TX PDO2 2nd mapped object
TX PDO2 3rd mapped object
TX PDO2 4th mapped object
Access
Type
RW
U32
RW
U16
RW
U16
R
U8
R
U32
R
U32
R
U32
R
U32
R
U8
R
U32
R
U32
R
U8
RW
U32
RW
U32
R
U8
RW
U32
RW
U8
RW
U8
RW
U32
RW
U32
RW
U32
RW
U32
RW
U8
RW
U32
RW
U32
RW
U32
RW
U32
R
U8
RW
U32
RW
U8
RW
U16
R
U8
RW
U32
RW
U8
RW
U16
RW
U8
RW
U32
RW
U32
RW
U32
RW
U32
RW
U8
RW
U32
RW
U32
RW
U32
RW
U32
Version 1.00 | Optidrive ODE-3 IP66 Outdoor Rated User Guide | 45
PDO Map
Default Value
N
00000080h+Node ID
N
0
N
0
N
4
N
0x0000031A
N
Drive Dependent
N
x.xx
N
Drive Dependent
N
2
N
00000600h+Node ID
N
00000580h+Node ID
N
2
N
40000200h+Node ID
N
254
N
2
N
C0000300h+Node ID
N
0
N
4
N
20000010h
N
20010010h
N
20030010h
N
00060010h
N
4
N
00060010h
N
00060010h
N
00060010h
N
00060010h
N
3
N
40000180h+Node ID
N
254
N
0
N
3
N
C0000280h+Node ID
N
0
N
0
N
4
N
200A0010h
N
200B0010h
N
200D0010h
N
20100010h
N
4
N
201 10010h
N
20120010h
N
20130010h
N
20140010h
9
Need help?
Do you have a question about the OPTIDRIVE E3 and is the answer not in the manual?
Questions and answers
Hi, problem with max speed p-01 50.0 p-02 0.0 p-03 5.0 only reaching 25.0 max speed 230v input 178v between phases output **** and cabling replaced many thanks
The Optidrive E3 may be limited to a maximum speed of 25.0 due to one or more of the following reasons:
1. Speed Reference Input (P00-03) – The speed reference input might be lower than expected, causing the drive to operate at a reduced speed.
2. Current Limit Reduction – If the overload accumulator reaches 90%, the output current limit is reduced to 100% of P-08, which could restrict the speed.
3. Analog Input Scaling – If an analog input is used for speed control, its scaling or signal level might be affecting the speed.
4. Alternative Ramp Time (P-24) – If P-24 is set and conditions apply, it could be affecting acceleration and deceleration speeds.
5. Derating at High Altitude or Temperature – If the drive is operating above 1000m or in high ambient temperatures, it may be derated, limiting performance.
Checking these factors and adjusting settings accordingly should help resolve the speed limitation.
This answer is automatically generated