9.1.1 PDO Default Mapping
Objects No.
RX
PDO1
TX
PDO1
RX
PDO2
TX
PDO2
* Drive control can only be achieved when P-12=7 or 8 provided that P-31 = 0, 1, 4 or 5.
9.1.2 PDO transmission type
Various transmission modes can be selected for each PDO. For RX PDO, the following modes are supported:
Transmission Type
0 – 240
254, 255
For TX PDO, the following modes are supported:
Transmission Type
0
1-240
254
255
9.1.3 CAN Open Specific Object Table
Index
Sub Index
1000h
0
1001h
0
1002h
0
1005h
0
9
1008h
0
1009h
0
100Ah
0
100Ch
0
100Dh
0
44 | Optidrive ODE-3 IP66 Outdoor Rated User Guide | Version 1.00
Mapped Object
1
2000h
2
2001h
3
2003h
4
0006h
1
200Ah
2
200Bh
3
200Dh
4
2010h
1
0006h
2
0006h
3
0006h
4
0006h
1
201 1h
2
2012h
3
2013h
4
2014h
Mode
The received data will be transferred to the drive active control register when the next sync
Synchronous
message is received.
Asynchronous
The received data will be transferred to the drive active control register immediately without delay.
Mode
TX PDO will only be sent out if the PDO data has changed and PDO will be transmitted on
Acyclic synchronous
reception of SYNC object.
TX PDO will be transmitted synchronously and cyclically. The transmission type indicates the
Cyclic synchronous
number of SYNC object that are.
Asynchronous
TX PDO will only be transferred once corresponding RX PDO has been received.
Asynchronous
TX PDO will only be transferred anytime if PDO data value has changed.
Function
Device Type
Error Register
Manufacturer Status Register
COB-ID Sync
Manufacturer Device Name
Manufacturer Hardware Version
Manufacturer Software Version
Guard Time (1ms)
Life Time Factor
Length
Mapped Function
Unsigned 16
Control command register*
Integer 16
Speed reference
Unsigned 16
User ramp reference
Unsigned 16
Unsigned 16
Drive status register
Integer 16
Motor speed Hz
Unsigned 16
Motor current
Integer 16
Drive temperature
Unsigned 16
Unsigned 16
Unsigned 16
Unsigned 16
Unsigned 16
DC bus voltage
Unsigned 16
Digital input status
Integer 16
Analog input 1 (%)
Integer 16
Analog input 2 (%)
Description
Description
Access
R
R
R
RW
R
R
R
RW
RW
Transmission Type
Valid immediately
Dummy
Send after receiving
Dummy
Dummy
Dummy
Dummy
Type
PDO Map
Default Value
U32
N
U8
N
U16
N
U32
N
00000080h
String
N
String
N
String
N
U16
N
U8
N
www.invertekdrives.com
254
254
RX PDO 1
254
254
0
0
0
ODE3
x.xx
x.xx
0
0
Need help?
Do you have a question about the OPTIDRIVE E3 and is the answer not in the manual?
Questions and answers
Hi, problem with max speed p-01 50.0 p-02 0.0 p-03 5.0 only reaching 25.0 max speed 230v input 178v between phases output **** and cabling replaced many thanks
The Optidrive E3 may be limited to a maximum speed of 25.0 due to one or more of the following reasons:
1. Speed Reference Input (P00-03) – The speed reference input might be lower than expected, causing the drive to operate at a reduced speed.
2. Current Limit Reduction – If the overload accumulator reaches 90%, the output current limit is reduced to 100% of P-08, which could restrict the speed.
3. Analog Input Scaling – If an analog input is used for speed control, its scaling or signal level might be affecting the speed.
4. Alternative Ramp Time (P-24) – If P-24 is set and conditions apply, it could be affecting acceleration and deceleration speeds.
5. Derating at High Altitude or Temperature – If the drive is operating above 1000m or in high ambient temperatures, it may be derated, limiting performance.
Checking these factors and adjusting settings accordingly should help resolve the speed limitation.
This answer is automatically generated