Epsilon EP-I Indexing Drive and FM-2 Indexing Module Reference Manual
When this index is complete then: Stop
Chain Count = 1
Index1
End of Index
Motion
End of Index
End of Index
Count
End of Chain
Count
Figure 68:
Example 1 – Index1 is chained to Index2 with a Chain Count of 1.
End of Index
Motion
End of Index
End of Index
Count
End of Chain
Count
Figure 69:
Example 2 – Index3 is chained to Index4 with a Chain Count of 2.
68
Index1
Index1
Dwell
Less than
10 usec
Index4
Index3
Index3
Dwell
Less Than
10 usec
Index2
Index1
Dwell
Index3
Index4
Dwell
Index2
Dwell
Index4
Index3
Index4
Dwell
Dwell