Codabar - Microscan MS-1 Integration Manual

Scan engine
Hide thumbs Also See for MS-1:
Table of Contents

Advertisement

Codabar

Codabar
Usage:
Used in photo-finishing and library applications. Previously used in medical
applications, but not typically used in newer medical applications.
Definition:
Codabar is a 16-bit character set (0 through 9, and the characters $, :, /, .,
+, and –) with start/stop codes and at least two distinctly different bar
widths.
Serial Cmd:
<K471,status,0,start/stop output status,0,symbol length status,symbol
length,check character status,check character output>
Default:
Disabled
Options:
0 = Disabled
Start/Stop Output Status (Codabar)
Definition:
When enabled, the start and stop characters will be present in the data output
of the decoded symbol.
When disabled, the start and stop characters will not be present in the data
output of the decoded symbol.
Note: Because the start and stop characters are included as part of the
data, the characters must be included as part of the length in a fixed length
mode of operation.
Serial Cmd:
<K471,status,0,start/stop output
length,check character status,check character output>
Default:
Enabled
Options:
0 = Disabled
Symbol Length Status (Codabar)
Definition:
When set to Any/Minimum, any symbol length is considered valid.
When set to Fixed, the MS-1 will check the symbol length against the
Symbol Length Status parameter.
Serial Cmd:
<K471,status,0,start/stop output
length,check character status,check character output>
Default:
Any/Minimum
Options:
0 = Any/Minimum
7-6
1 = Enabled
status,0,symbol length status,symbol
1 = Enabled
status,0,symbol length
1 = Fixed
MS-1 Scan Engine Integration Manual