No Decode Timeout

Usage:
Useful in tightly-controlled applications that require a read cycle to end
before the next object appears.
Definition:
The duration of the read cycle as measured from either the beginning of the
read cycle or from the last decode.
Serial Cmd:
<K220,0,seconds>
Note: The first parameter is always a zero (0) and does not change.
Default:
2
Options:
1 - 4095
The MS-1 times out if no symbol is decoded during the No Decode Timeout period. If a
symbol is decoded before the timeout expires, the timeout period starts again.
No Decode Timeout only applies to Edge, Serial Data, and Serial Data and Edge trigger
modes.
In Single symbol mode (<K222,1>), No Decode Timeout is the maximum amount of time
the MS-1 will attempt to decode after a trigger is activated.
In Multiple symbol mode (<K222,0>), No Decode Timeout is the time in which there are
no decodes—not the time since the trigger was activated. That is, if the MS-1 continues to
decode symbols presented to it, it will not exit the read cycle unless the time between
decodes exceeds the time set in No Decode Timeout.
For Level trigger mode, the read cycle ends when the trigger falls, or when a symbol is
decoded and output in Single symbol mode.