Gs1 Databar (Rss) - Microscan MS-1 Integration Manual

Scan engine
Hide thumbs Also See for MS-1:
Table of Contents

Advertisement

GS1 DataBar (RSS)

GS1 DataBar (RSS)
Note: GS1 DataBar symbologies were previously known as "Reduced Space Symbology",
or "RSS".
DataBar-14 (RSS-14)
Note: DataBar-14 was previously known as "RSS-14".
Usage:
Used in the grocery, retail, and prescription drug industries where 14-digit
EAN item identification may be needed.
Definition:
DataBar-14 is a minimum length symbology that encodes 14 digits, including
a 1-digit indicator. DataBar-14 is 96 modules wide. It can be stacked in two
rows, it can read omnidirectionally if printed in full height, or horizontally if
height-truncated for small marking.
Serial Cmd:
<K482,status>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
DataBar Limited (RSS Limited)
Note: DataBar Limited was previously known as "RSS Limited".
Usage:
DataBar Limited is designed to be read by laser scanners and CCD readers.
It is not recommended for omnidirectional slot scanners.
Definition:
Encodes a smaller 14-digit symbol (74 modules wide) that is not omnidirectional.
Serial Cmd:
<K483,status>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
DataBar Expanded (RSS Expanded)
Note: DataBar Expanded was previously known as "RSS Expanded".
Usage:
Used to encode primary and supplementary data in retail point-of-sale and
other applications.
Definition:
DataBar Expanded is a variable length symbology that can encode supplementary
information in addition to the 14-digit EAN item identification number and is
capable of encoding up to 74 numeric or 41 alphabetic characters.
Serial Cmd:
<K484,status>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled