Installation

Grounding

The equipment must be grounded to reduce the
risk of static sparking and electric shock. Electric
or static sparking can cause fumes to ignite or
explode. Improper grounding can cause electric
shock. Grounding provides an escape wire for the
electric current.
NOTE: The ProControl 1KE does not provide 500
VAC isolation through the coupling nuts on the
enclosure. The associated apparatus and the field
apparatus cable shields must not be connected to
the ProControl 1KE coupling nuts.
12
1. Power Supply 16M167: Connect the ground wire
from the power supply to a true earth ground.
2. ProControl 1KE Module: Connect a ground
wire and clamp to the screw on the top of the
bracket. Connect the other end to ground. In an
IS system, the ProControl 1KE also is grounded
by connection to the grounded power supply.
3. Flow Meter: Follow the instructions in manual
308778 (G3000) or manual 313599 (Coriolis) to
ground the flow meter and check its electrical
grounding continuity.
4. Fluid and Air Control: Ground through connection
to the mounting panel that also holds the
grounded flow meter.
5. Fluid Supply: Ground the fluid supply unit.