Setup Screens

Setup Screen 4

Use this screen to set your alarm preferences. Select
to enable the alarm, or leave the box empty to
disable the alarm.
Enter the screen to set or change
preferences.
Press to toggle between
Maintenance Totalizer Alarm Enable
Flow Rate Alarm Enable
Alarm Auto Clear Enable. If enabled,
when the flow rate returns to within the
flow limit set points, the flow rate alarm
will clear on the screen and on any
attached accessories, such as a the light
tower.
Set backlight timer. Enter "00" to set the
backlight to remain on.
Exit data editing.
Move between Setup Screens, fields on
a screen, or to increment/decrement the
digits when editing number fields.
28
Key
and blank.

Setup Screen 5

Use this screen to calibrate your meter and
to view or set your meter k-factor. See
Calibrate the Meter, page
Enter the screen to set or change
preferences.
Press to activate a field for editing or
to accept the highlighted selection on a
dropdown menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.
Start the calibration.
Stop the calibration.
Displays the volume measured by the
system for the calibration test.
Enter the actual volume dispensed into
the cylinder for the calibration test.
Displays the meter k-factor. User can
set the k-factor manually. The system
automatically updates to the correct
k-factor when the meter is calibrated.
Exit data editing.
Move between Setup Screens, fields on
a screen, or to increment/decrement the
digits when editing number fields.
18, for procedure.
Key
3A2614H