Grounding

1. Always ground the fluid supply unit, using one of the
following options:
a. Mount the meter to a grounded conductive sur-
face, or
b. Connect the conductive fluid hose to the meter
inlet and outlet.
c. Connect a ground wire to the meter's M6
mounting holes.
6
2. Never use the flow meter with an electrostatic gun
isolation stand.
Sensor Connector Pin-out
4
1
3
2
NOTE: This drawing shows the pin connector used
on meters 246190 Series D, 246340 Series D,
246652 Series C, and newer. Older meters used a
5-pin connector.
Sensor Kit 246786 now includes a cable with a 4-pin
connector, to replace the existing cable connection.
F
. 2
IG
Pin 1: +10-30 Vdc Supply
Pin 2: Signal Out
Pin 3: Ground
Pin 4: No Connection