Air Connections

NOTICE
To avoid damage to the I/P transducer, use clean,
dry, oil-free air, filtered through at least a 40 micron
filter.
Communication Options
Graco Accessories are available to enable
communication with a Programmable Logic
Controller (PLC) or Personal Computer (PC).
• The Fiber Optic Converter (Graco Kit 24N978)
enables Modbus RTU communication with a
user-supplied PLC using a serial cable.
• A Modbus Gateway (Graco Kit 24N977) used
with a Fiber Optic Converter (Graco Kit 24N978)
enables Modbus TCP communication with a
user-suppled PLC.
3A2614H
1. Connect incoming air line (Q) to 1/4 in. npt (f)
inlet (AB) on I/P transducer (T). Kits with a fluid
regulator (See
Parts, page
tube fitting.
2. Kits with fluid regulator: Check that the air tube
is connected from 5/32 tube fitting (AC) on I/P
transducer to 5/32 tube fitting (AH) on fluid
regulator (N).
Other Kits: The air outlet is 1/4 in npt (f).
The I/P transducer exhausts a small amount of air
whenever air is connected, whether or not the system
is operating.
NOTE:
• The side port (AD) on the fluid regulator can be
used for high-speed flushing with an independent
air source. Set the air pressure higher than the top
port (AH) air pressure.
• Flushing air pressure must be removed from the
side port (AD) to return to the previous flow setting.
• A Modbus Gateway (Graco Kit 24N977)
can be connected to (or installed in)
an Advanced Web Interface (Graco
Kit 15V377) to enable communication
with a PC using an ethernet cable. See
Appendix B - Advanced Web Interface, page
for instructions.
These communication kits come with installation
and setup directions necessary for their use with the
ProControl 1KE.