Setup Screen 6

Use this screen to specify your pressure transducer
and set its offset and slope.
Enter the screen to set or change
preferences.
Press to activate a field for editing or
to accept the highlighted selection on a
dropdown menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.
Select the correct pressure transducer.
Set the zero offset (the reading on
the gauge when no pressure is on the
system).
Pressure transducer slope. This number
is a constant representing millivolts
per bar. The default matches the
selected pressure transducer. Operator
adustable.
Exit data editing.
Move between Setup Screens, fields on
a screen, or to increment/decrement the
digits when editing number fields.
3A2614H
Key

Setup Screen 7

Use this screen to set your modbus preferences
for ports 1 and 2. Note that ports 5 and 6 are used
as modbus master devices for connecting to other
ProControl 1KE (or Informer) modules.
Modbus mode. Select off or Slave from
the dropdown options.
Turn off Modbus functionality if
not used.
Use ProControl 1KE as Modbus
slave device.
Enter or change the Modbus address.
Value is between 1 and 247.
Select serial port baudrate from the
dropdown options: 9600, 19200, 38400,
57600, or 115200.
Select serial port parity from the
dropdown options: NONE, ODD, or
EVEN.
Exit data editing.
Move between Setup Screens, fields on
a screen, or to increment/decrement the
digits when editing number fields.
Setup Screens
Key
29