Emergency Opening; Dismantling - Kentix AlarmManager-BASIC User Manual

Hide thumbs Also See for AlarmManager-BASIC:
Table of Contents

Advertisement

9.3.6.

Emergency opening

If the batteries have not been replaced during the three warning stages, an emergency opening with the help of
the low-power-adapter is required at an online knob.
Low-Power-Adapter
For this purpose the front cover (Kentix logo) at the knob is removed using the supplied suction cup.
Now the low-power-adapter can be put onto the contacts at the knob. Single bookings can then be made.
Perform a booking with the battery changing card and replace the batteries as described above.
9.3.7.

Dismantling

Using the dismantling card, the knob can be pulled off from the profile cylinder. There are no extra tools
required.
To remove the knob, hold the dismantling card in front of it. The knob goes into the dismantling position. By
simultaneous turning and slight pulling the knob can be pulled off the cylinder.
To quit the dismantling position, the dismantling card has to be held in front of the knob once again.
NOTE!
The removal of the knob is only possible in one position. To reach this position slowly turn it to left or right.
Depending on the position, a full turning of 360° might be necessary.
Page
96
Online knob without cover
(06-2017, subject to change)
Contacts for emergency
opening
Place Low-Power-Adapter
here
kentix.com