The RFID-cards for the users are also added with the programming mode in the offline-mode:
No
Present Servicekey card (yellow) in front of
1
DoorLock-devices reader unit to start the
programming mode.
Present RFID user card in front of the reader unit.
2
Present Servicekey card (yellow) in front of the
3
reader unit to leave programming mode.
It is also possible to remove single RFID user-cards by presenting them again during programming mode:
No
Present Servicekey card (yellow) in front of
1
DoorLock-devices reader unit to start the
programming mode.
2
Present RFID user card in front of the reader unit.
Present Servicekey card (yellow) in front of the
3
reader unit to leave programming mode.
NOTE!
In offline mode a DoorLock-device must be reset to delete lost RFID user cards.

For a description please read the chapter „Reset components" later in this manual.
Page
83
Step
Step
(06-2017, subject to change)
Note / Signalization
1x long sound, 1x short sound
wait for 5 seconds
2x short sound, LEDs light green
wait for 5 seconds, then the next card can be directly learned
1x short sound, 1x long sound
Note / Signalization
1x long sound, 1x short sound
wait for 5 seconds
2x long sound, LEDs light red
wait for 5 seconds, then the next card can be directly learned
1x short sound, 1x long sound