Installing The Fabric Processor Kit - Intel S7200AP System Integration And Service Manual

Table of Contents

Advertisement

2.10.3

Installing the Fabric Processor Kit

1.
Power off the compute module and disconnect the power cable(s).
2.
Remove the air duct.
3.
See section 2.4.1
CPU carrier assembly and mount it onto the server board. Note that the fabric carrier clip that comes
with the kit must be used with the fabric CPU.
4.
Remove the Fabric Processor Kit components
5.
For ease of installation, prior to installing the carrier card into Riser 1, install the sideband cable (P2,
black end) into carrier card connector J3A1 on the carrier card (See letter A in figure 51). Leave the
other end of the cable (P1, white end) disconnected for later installation into the main board
sideband fabric connector J5J2.
6.
PCSD customers should ensure that IFT Carrier Card Jumper J1A2 is set for pin position 2-3 for
normal operation.
NOTE: The actual view of the IFT carrier card has been modified in order to illustrate the sideband
cable connection (See Figure 51). The card will be rotated 180° and thee IFT carrier ports face down
in Riser Slot 1 when installed in the system.
7.
Install the IFT carrier card.
Note: The IFT card should be installed in PCIe* Slot 1 for normal operation with the Intel® Xeon™ Phi™
(Fabric) processor. The IFT carrier card is not supported in PCIe* Slot 2 when the fabric CPU is
installed. When the Intel® Xeon™ Phi™ (Fabric) processor is used in the server system, PCIe* Slot 2 is
reduced to x4 lanes (electrical) for PCIe* device connectivity. See the Intel
and Intel® Compute Module HNS7200AP Product Family Configuration Guide and Technical Product
Specification for Riser 2 options.
a) Follow the basic instructions to install an Add-In-Card in Slot 1 as shown in
IFT card into Riser Slot 1 card (See Figure 52, letter A). Note that the sideband cable (P2, black end)
is already connected to the IFT carrier card prior to installing the carrier card into Riser 1.
b) Install IFT and Riser Slot 1 card into Riser slot 1 (See Figure 52, letter B).
c) Secure the riser card (See Figure 52, letter C).
d) Once the IFT Carrier Card is fully secured in the system, connect the other end of the sideband cable
(P1, white end) into the main board sideband fabric connector J5J2. Refer back to Figure 51 (See
See section
2.3.1.
for instructions on how to assemble the (processor heat sink module) PHM, fabric
Figure 69. Sideband Cable Connection
®
Server Board S7200AP
section
2.7.1. Install the

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S7200aprHns7200apHns7200apr

Table of Contents