Inspiratory and Expiratory Resistance (cm H
Inspiration
0.6
Expiration
1.0
Anti asphyxia valve (AAV) open-to-atmosphere pressure (cm H
≤ 1.6
Anti asphyxia valve (AAV) closed-to-atmosphere pressure (cm H
≤ 1.8
Sound - DECLARED DUAL-NUMBER NOISE EMISSION VALUES in accordance with ISO
4871. The A-weighted sound power level and the A-weighted sound pressure level of
the mask, at a distance of 1M, with uncertainty of 3 dBA, are shown.
Power Level
28 dBA
Pressure level
20 dBA
at 1m
Gross Dimensions - Mask fully assembled - no headgear. Largest variant only shown.
Height 172 mm
Width 103 mm
Depth 107 mm
Mask setting options: Select A if available, otherwise select B.
A Full Face
B Mir Full
Environmental conditions – all masks:
Operating temperature: +5°C to +40°C
Operating humidity: 15% to 95% non-condensing
Storage and transport temperature: –20°C to +60°C
Storage and transport humidity:
Quattro FX/
Quattro
Liberty
Quattro FX
for Her
O)
2
0.7
0.8
0.7
0.7
0.8
0.8
O)
2
<= 1.8
<= 1.8
O)
2
<= 1.8
<= 1.8
27 dBA
26 dBA
24 dBA
19 dBA
18 dBA
16 dBA
140 mm
206 mm
100 mm
176 mm
109 mm
110 mm
144 mm
108 mm
100 mm
Mir Full
Mir Full
Mir Full
Full Face
Full Face
Full Face
up to 95% non-condensing
Storage
Ensure that the mask is thoroughly clean and dry before storing it for any length
of time. Store the mask in a dry place out of direct sunlight.
(Quattro FX/Quattro FX for Her only) To maintain optimum care of your mask,
ensure the spring frame support is fitted when travelling.
Disposal
The mask does not contain any hazardous substances and may be disposed of
with your normal household refuse.
The following symbols may appear on the mask or packaging.
Caution, consult accompanying documents;
Number;
European Authorised Representative;
limitation;
Humidity limitation;
Manufacturer;
Keep away from rain;
with care.
Warnings
• The mask should only be used with CPAP or bilevel devices recommended by a
physician or respiratory therapist.
• As with all masks, some rebreathing may occur at low CPAP pressures.
• The vent holes must be kept clear.
• The mask should not be used unless the device is turned on. Once the mask is
fitted, ensure the device is blowing air.
• Follow all precautions when using supplemental oxygen.
• Oxygen flow must be turned off when the CPAP or bilevel device is not
operating so that unused oxygen does not accumulate within the device
enclosure and create a risk of fire.
• At a fixed flow rate of supplemental oxygen flow, the inhaled oxygen
concentration varies depending on the pressure settings, user breathing
pattern, mask, point of application and leak rate.
• If any visible deterioration of a mask component is apparent (cracking, tears,
etc), the mask component should be discarded and replaced.
25
Batch Code;
Catalogue
LOT
REF
Temperature
Not made with natural rubber latex;