Appliance Installation; Unpacking The Fire; Gas Connection; Preparing The Fireplace - Vision V1/200/A Installation & User's Instructions

Inset coal effect gas convector fire
Table of Contents

Advertisement

APPLIANCE INSTALLATION

UNPACKING THE FIRE

Carefully remove the appliance from the carton, taking special care with any ceramic
components. Remove all loose item packaging and check for all components which should
include:
1 x Firebox with burner assembly
1 x Box containing ceramic components.
1 x Installation and User Instruction manual
1 x Loose parts pack including:
1 x Strip of floor sealing tape
1 x Inlet 'T' connector
2 x Grommet for rear of firebox
4 x Woodscrews
6 x Fibre/wooden plugs
4 x Eyebolts
2 x Tension cables
2 x Cable adjusters
1 x Foam Seal
2 x Fascia fixing screws
1 x Battery (ezi-slide model only)

GAS CONNECTION

A concealed gas connection is recommended. If concealed pipework is required then steps must
be taken to extend the supply line so that it enters the firebox through the supply hole at the
bottom right hand side. The pipe should run through the supply hole and to the inlet 'T' connector
towards the front of the fire. Please ensure that the supply pipework does not encroach on the
space required to fit the firebox into the fire opening. The inlet 'T' connector features a valve for
isolating the gas
supply and a pressure test point. After installation, connect a suitable pressure
test gauge to the pressure test point on the inlet 'T'. With the fire lit check that the supply pressure
is 20
±1.5mbar. Disconnect the pressure gauge and check for gas soundness.
PREPARING THE APPLIANCE
Take the burner unit out of the fire box by removing the two
screws and gently lifting away (Fig. 1). If the fire is a slide
control then the slide mechanism must be disconnected first
see page 13 of this manual for details.
Fit the foam seal to the rear of the firebox side and top
REMOVE 2 SCREWS
flanges. Carefully measure and cut each piece ensuring that
it is not overstretched and that there are no gaps where each
piece of foam meet. A complete seal must be achieved
Fig. 1
around the three flanges.
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

V1/200/b

Table of Contents