Vision V1/400/A Installation & User's Instructions

Decorative open front coal effect gas fire

Advertisement

Quick Links

V1/400/A
Model Number:
(manual control)
DECORATIVE OPEN FRONT
COAL EFFECT GAS FIRE
INSTALLATION & USER INSTRUCTIONS
GB IE
SUITABLE FOR USE ON NATURAL GAS (G20) AT 20mbar SUPPLY PRESSURE
These instructions must be left with the appliance for future reference and
V1/100 Rev.1 (Dec 2011)
VISION FIRES

Advertisement

Table of Contents
loading

Summary of Contents for Vision V1/400/A

  • Page 1 V1/400/A Model Number: (manual control) DECORATIVE OPEN FRONT COAL EFFECT GAS FIRE INSTALLATION & USER INSTRUCTIONS GB IE SUITABLE FOR USE ON NATURAL GAS (G20) AT 20mbar SUPPLY PRESSURE These instructions must be left with the appliance for future reference and V1/100 Rev.1 (Dec 2011)
  • Page 2: Table Of Contents

    CONTENTS TECHNICAL INFO Appliance Information Efficiency Information Ventilation Requirements INSTALLATION REQUIREMENTS General Installation Conditions Flue/Chimney Suitability and Inspection Preparation of the Fireplace Opening Shelf Position Fireguard Requirements APPLIANCE INSTALLATION Unpacking the Fire Fitting the Appliance Fuel Bed Assembly Fire Front Lighting the Appliance Spillage Test Review &...
  • Page 3: Technical Info

    TECHNICAL INFORMATION APPLIANCE INFORMATION This appliance should be used with Natural Gas (G20) only. Model: V1/400/A Gas Type G20 natural gas Maximum Gross Input 6.85kW (23,400 Btu/h) Minimum Gross Input 3.8kW (13,000 Btu/h) Inlet Pressure 20mbar ±1.5mbar Gas Connection 8mm pipe...
  • Page 4: Installation Requirements

    INSTALLATION REQUIREMENTS GENERAL INSTALLATION CONDITIONS In the United Kingdom it is law that all gas appliances are fitted by a competent person in accordance with the most up to date edition of the Gas Safety (Installation and Use) Regulations. Failure to install the appliance correctly could lead to prosecution. The installation must also be in accordance with all relevant parts of the Local and National Building Regulations, all relevant code of practice, and all applicable requirements of the following British Standards:...
  • Page 5: Preparation Of The Fireplace Opening

    INSTALLATION REQUIREMENTS PREPARATION OF THE FIREPLACE OPENING The appliance must be installed mounted on a non-combustible hearth. It must not be installed directly on any combustible material. The hearth must be at least 12mm thick with a periphery thickness of at least 50mm. It should be at least 700mm wide and project at least 300mm for- wards from the fire opening.
  • Page 6: Appliance Installation

    APPLIANCE INSTALLATION UNPACKING THE FIRE Carefully remove the appliance from the carton, taking special care with any ceramic components. Remove all loose item packaging and check for all components which should include: 1 x Gas fire burner assembly 1 x Box containing ceramic components. 1 x Installation and User Instruction manual 1 x Loose parts pack including: 1 x Inlet ‘T’...
  • Page 7: Fuel Bed Assembly

    APPLIANCE INSTALLATION FUEL BED ASSEMBLY Take the one-piece ceramic coal front and gently place it in front of the ceramic burner (factory- clamped to the burner tray). Then take the ceramic coal matrix and place it on top of the ceramic burner.
  • Page 8 APPLIANCE INSTALLATION Take 4 of the large coals and position them as shown in Fig. 9 below. Fig. 7 Fig. 9 Take the two small coals and position them as shown in Fig. 10 below. Fig. 10...
  • Page 9 APPLIANCE INSTALLATION Take 3 of the large coals and position them as shown in Fig. 11 below. Take the remaining two medium coals and position them as shown in Fig. 12 below. Fig. 11 Fig. 12 Only use the coals that are supplied with this appliance. If replacement coals are required, use only a full genuine replacement set.
  • Page 10: Fire Front

    APPLIANCE INSTALLATION FIRE FRONT This appliance can be used with several different Vision Fires frets. Any fret to be used must conform to the following dimensions (Fig. 13). MINIMUM OPEN AREA OF MINIMUM OPEN TOTAL OPEN AREA OF FRET FRET = 11,000mm²...
  • Page 11: Spillage Test

    APPLIANCE INSTALLATION SPILLAGE TEST Close all of the doors and window in the room of the appliance. Ignite the appliance and set to ‘HI’ position. After 5 minutes hold a smoke match inside the fire. This should be positioned centrally, 20mm from the top edge and flush with the front face of the fire- place opening.
  • Page 12: Servicing And Maintenance

    SERVICING & MAINTENANCE SERVICING Servicing should be carried out a least once a year by a competent person. Failure to do so will void the appliance warranty. Ensure that the fire is turned off and it is cool. The service should include a visual inspection of the chimney and fire opening for any debris. All ceramic components should be inspected and if necessary, should be replaced with a genuine full set.
  • Page 13: User Guide

    USER GUIDE IF YOU SMELL GAS Turn off gas supply immediately. Extinguish all flames. Do not smoke. Do not operate any electrical switches (on or off). Open doors and windows to ventilate the area. Call the Gas Emergency Service - consult your local telephone directory for information. GENERAL INFORMATION In the United Kingdom it is law that all gas appliances are fitted by a competent person in accordance with the most up to date edition of the Gas Safety (Installation and Use) Regulations.
  • Page 14: Operating Procedure

    USER GUIDE If the appliance is fitted to a wall without a fire surround then any wall covering must be non com- bustible. Soft wall coverings such as wallpaper, blown vinyl are easily affected by heat and shouldn't be used unless a fire surround is fitted. Do not add extra ceramic pieces to the appliance as this can result in incorrect combustion.
  • Page 15: Spillage Safety System

    USER GUIDE SPILLAGE SAFETY SYSTEM For safety, this appliance is fitted with an oxygen sensitive pilot system. This will cut off the gas supply to the appliance if the oxygen level in the room falls below its normal level. If this happens it usually indicates that there is a problem with the flue system.
  • Page 16 VISION FIRES IMPERIAL POINT EXPRESS TRADING ESTATE STONE HILL ROAD FARNWORTH BOLTON BL5 9TN WWW.VISIONFIRES.COM TEL: 01204 868 550...

Table of Contents