LIGHTING THE APPLIANCE

Manual Control
Open the gas isolation valve.
Push the control knob and turn fully anti clockwise to the position marked 'P' for Pilot.
Hold the control knob here until the pilot lights. Hold for a further 10 seconds to allow a
stable flame.
Release the control knob and turn anti clockwise to the 'HI' position to ignite the main
burner.
Turn the control knob clockwise to the 'LO' position to switch the fire to its minimum heat
setting.
Push the control knob and turn clockwise to the 'P' position to extinguish the main burner
while leaving the pilot flame alight.
Push the control knob and turn fully clockwise to the 'O' position to extinguish the pilot
flame. The appliance is now turned off.
Slide Control
Open the gas isolation valve.
Push the control lever fully down to the 'P' position and hold there until the pilot
lights. Hold for a further 10 seconds to allow a stable flame.
Release the control lever and it will automatically raise to the 'LO' position. The
fire is now at minimum heat setting.
Lift the control lever up to the 'HI' position. You will feel a positive location check
when the lever reaches this setting.
Lift the control lever fully up to the 'O' position to extinguish the pilot and main
burner. The appliance is now turned off.
FLUE RESTRICTOR
The appliance is supplied with a front fixing flue
restrictor. Generally the restrictor is not required but if
the flue is found to be pulling excessively then it can be
fitted by offering it up to the 3 heat exchange tubes
and securing using the two screws provided.
See Fig. 12.