GENERAL INSTALLATION CONDITIONS

In the United Kingdom it is law that all gas appliances are fitted by a competent person in
accordance with the most up to date edition of the Gas Safety (Installation and Use) Regulations.
Failure to install the appliance correctly could lead to prosecution.
The installation must also be in accordance with all relevant parts of the Local and National
Building Regulations, all relevant code of practice, and all applicable requirements of the
following British Standards:
BS EN 1856 Part 1
BS 715 -
BS EN 1858
BS EN 1806
BS EN 1856 Part 1
BS 5440 Parts 1 & 2
BS 6461 Part 1
BS 5871 Part 2
BS 6891

FLUE/CHIMNEY SUITABILITY AND INSPECTION

This appliance is for use with 225mm x 225mm conventional brick built chimneys and fabricated
flues. Any chairbrick must be removed.
If the chimney has previously been used for solid fuel, the chimney must be swept before
installation of the appliance.
Minimum size of all flues: 125mm diameter or equivalent area. On 125mm diameter and pre-
cast flues the restrictor must not be fitted.
Minimum effective height of all flue types: 3 metres.
Single wall, twin wall or flexible flue liner must be stainless steel or aluminium and conform to BS
EN 1856 Part 1.
The flue system must conform to BS 5440 Part 1 in design and installation.
The flue must not be used for any other appliance. Any dampers or register plates must be
removed or locked in the open position.
If a metal flue box (to BS 715) is used it must be totally insulated with a minimum of 50mm of
suitable insulation.

INSTALLATION REQUIREMENTS

Chimneys - Requirements for metal chimneys.
Specification for metal flue boxes or gas fired appliances not
exceeding 20kW.
Chimneys - Components - Concrete flue blocks.
Chimneys - Clay/ceramic flue blocks.
Chimneys - Requirements for metal chimneys.
Installation of Flues and Ventilation.
Masonry chimneys & flues - Installation.
Installation - Inset LFE gas fires.
Gas pipework installation.