Page 1
V1/200/A Model Number: (manual control) V1/200/B (ez-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE INSTALLATION & USER INSTRUCTIONS GB IE SUITABLE FOR USE ON NATURAL GAS (G20) AT 20mbar SUPPLY PRESSURE These instructions must be left with the appliance for future reference and for servicing information.
CONTENTS TECHNICAL INFO Appliance Information Efficiency Information Ventilation Requirements INSTALLATION REQUIREMENTS General Installation Conditions Flue/Chimney Suitability and Inspection Preparation of the Fireplace Opening Fireplace Opening Size Shelf Position Fireguard Requirements APPLIANCE INSTALLATION Unpacking the Fire Gas Connection Preparing the Fireplace Installing the Firebox Fuel Bed Assembly Fascia...
TECHNICAL INFORMATION APPLIANCE INFORMATION This appliance should be used with Natural Gas (G20) only. Model: V1/200/A - manual control V1/200/B - slide control Gas Type G20 natural gas Maximum Gross Input 6.0kW (20,450 Btu/h) Minimum Gross Input 3.7kW (12,600 Btu/h) - manual control 2.9kW (9,900 Btu/h) - slide control...
INSTALLATION REQUIREMENTS GENERAL INSTALLATION CONDITIONS In the United Kingdom it is law that all gas appliances are fitted by a competent person in accordance with the most up to date edition of the Gas Safety (Installation and Use) Regulations. Failure to install the appliance correctly could lead to prosecution. The installation must also be in accordance with all relevant parts of the Local and National Building Regulations, all relevant code of practice, and all applicable requirements of the following British Standards:...
INSTALLATION REQUIREMENTS PREPARATION OF THE FIREPLACE OPENING The appliance must be installed mounted on a non-combustible hearth. It must not be installed directly on any combustible material. The hearth must be at least 12mm thick with a periphery thickness of at least 50mm. It should be at least 700mm wide and project at least 300mm for- wards from the fire opening.
APPLIANCE INSTALLATION UNPACKING THE FIRE Carefully remove the appliance from the carton, taking special care with any ceramic components. Remove all loose item packaging and check for all components which should include: 1 x Firebox with burner assembly 1 x Box containing ceramic components. 1 x Installation and User Instruction manual 1 x Loose parts pack including: 1 x Strip of floor sealing tape...
APPLIANCE INSTALLATION INSTALLING THE FIREBOX There are two options of fixing the firebox into the fire opening/fireplace surround. Option 1 - Front Fixing Offer the firebox into the opening ensuring that the supply pipe is correctly positioned. When the firebox is in the FIXING LOCATIONS intended position of installation make a mark through the holes indicated on Fig.
APPLIANCE INSTALLATION Do not over tighten the cables. Check that there are no gaps around the foam strips. Using the sealing tape supplied, create a seal between the bottom face of the firebox and the fireplace floor. Reposition the burner and secure with the two screws previously removed.
Page 9
APPLIANCE INSTALLATION Take 5 of the large coals and position them as shown in Fig. 7 below. Fig. 7 Take 4 of the large coals and position them centrally as shown in Fig. 8 below. Fig. 8...
If the appliance uses a slider control then reconnect the slider arm to the gas control pivot. FASCIA This appliance can be used with several different Vision Fires fireframes or frets. For full instructions on how to fit them please refer to the guide that is supplied with them.
APPLIANCE INSTALLATION LIGHTING THE APPLIANCE Manual Control Open the gas isolation valve. Push the control knob and turn fully anti clockwise to the position marked ‘P’ for Pilot. Hold the control knob here until the pilot lights. Hold for a further 10 seconds to allow a stable flame.
APPLIANCE INSTALLATION SPILLAGE TEST Close all of the doors and window in the room of the appliance. Ignite the appliance and set to ‘HI’ position. After 5 minutes hold a smoke match inside the fire. This should be positioned centrally, just underneath the convection channel at the top of the fire.
SERVICING & MAINTENANCE SERVICING Servicing should be carried out a least once a year by a competent person. Failure to do so will void the appliance warranty. Ensure that the fire is turned off and it is cool. The service should include a visual inspection of the chimney and fire opening for any debris. All ceramic components should be inspected and if necessary, should be replaced with a genuine full set.
SPARES Below you will find a list of all of the spares you may require for future service and maintenance purposes. ITEM CODE Ceramic Coals (loose) Complete Set VLS200-GL004-10 Ceramic Front Coal (one piece) VLS100-GL002-11C Ceramic Matrix VLS200-GL004-10B Ceramic Burner VLS200-GL004-10A Brick Set VLS200-GL004-10D...
USER GUIDE IF YOU SMELL GAS Turn off gas supply immediately. Extinguish all flames. Do not smoke. Do not operate any electrical switches (on or off). Open doors and windows to ventilate the area. Call the Gas Emergency Service - consult your local telephone directory for information. GENERAL INFORMATION In the United Kingdom it is law that all gas appliances are fitted by a competent person in accordance with the most up to date edition of the Gas Safety (Installation and Use) Regulations.
USER GUIDE If the appliance is fitted to a wall without a fire surround then any wall covering must be non com- bustible. Soft wall coverings such as wallpaper, blown vinyl are easily affected by heat and shouldn't be used unless a fire surround is fitted. Do not add extra ceramic pieces to the appliance as this can result in incorrect combustion.
USER GUIDE OPERATING PROCEDURE Slide Control The control lever is located to the top right hand side of the fire/fascia. Push the control lever fully down to the ‘P’ position and hold there until the pilot lights. Hold for a further 10 seconds to allow a stable flame. Release the control lever and it will automatically raise to the ‘LO’...
Use a lightly damp cloth to wipe away any dirt or marks from the metalwork. FASCIA This appliance can be used with several different Vision Fires fascia's or frets. For full instructions on how to fit them please refer to the guide that is supplied with them.