Fuse - Kubota B2301 Workshop Manual

Hide thumbs Also See for B2301:
Table of Contents

Advertisement

B2301, B2601, WSM

[2] FUSE

1. When inspecting the circuit line, check the related fuses. For the detail of the fuses, refer to the page G-34.
2. If any of the fuse is blown, replace with a new one of the same capacity.
IMPORTANT
• If a fuse is blown, check the cause and be sure to replace it with a new one of the same capacity.
Recharging
CAUTION
• When the battery is being activated, hydrogen and oxygen
gases in the battery are extremely explosive. Keep open
sparks and flames away from the battery at all times,
especially when charging the battery.
• When disconnecting the cable from the battery, start with
the negative terminal first.
When connecting the cable to the battery, start with the
positive terminal first.
• Never check battery charge by placing a metal object
across the posts.
Use a voltmeter or hydrometer.
1. To slow charge the battery (1), connect the battery positive
terminal to the charge positive terminal and the negative to the
negative, then recharge in the standard fashion.
2. A boost charge is only for emergencies. It will partially charge
the battery at a high rate and in a short time.
When using a boost-charged battery, it is necessary to recharge
the battery as early as possible.
Failure to do this will shorten the battery's service life.
3. The battery is charge if the indicator display turns green from
black.
4. When exchanging an old battery for a new one, use battery of
equal specification shown in table.
Table
Battery
Capacity
Volt (V)
Type
at 5 H.R.
55B24L
12
(S)-MF
(1) Battery
Directions for Storage
1. When shutting down the tractor for long periods of time, remove
the battery from the tractor, store the battery in a well ventilated
placed where it is not exposed to direct sunlight.
2. Since the battery self-discharges by approx. 0.5 % per day even
in storage, it must be once every two months in cold season.
3. When storing the battery mounted on the tractor, disconnect the
ground cable from the battery's negative terminal post.
(Reference)
• Self-discharge Rate
Temperature
30 °C (86 °F)
20 °C (68 °F)
10 °C (50 °F)
8-S11
ELECTRICAL SYSTEM
Cold
Reserve
Cranking
at (min.)
Amps
36
80
430
(2) Indicator
9Y1211156ELS0008US0
Self-discharge rate
Approx. 1.0 % per day
Approx. 0.5 % per day
Approx. 0.25 % per day
9Y1211156ELS0009US0
9Y1211156ELS0010US0
KiSC issued 11, 2014 A
Normal
Charging
Rate (A)
4.5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B2601

Table of Contents