Service As Required; Bleeding The Fuel System; Replacing The Fuse - Kubota BX1880-AU Operator's Manual

Table of Contents

Advertisement

SERVICE AS REQUIRED

SERVICE AS REQUIRED

1. Bleeding the fuel system

Air must be removed:
• When the fuel filter or lines are removed
• When the tank is completely empty
• After the tractor has not been used for a long period
of time
Bleeding procedure is as follows
1. Fill the fuel tank with fuel.
(1) Fuel pump
2. Turn the key switch to the on
following seconds.
Turning the key to on for the following seconds
allows fuel pump to work and pump air out of the
fuel system.
Turning the key to on
3. Start the engine and run it for the following
seconds, and then stop it.
Running the engine

2. Replacing the fuse

The electrical system of the tractor is protected from
potential damage by fuses.
A blown fuse indicates that there is an overload or short
somewhere in the electrical system.
1. If any of the fuses should blow, replace with a new
fuse with the same capacity.
IMPORTANT :
• Before replacing a blown fuse, determine why
the fuse blew and perform any necessary
repairs.
Failure
procedure may result in serious damage to the
electrical system of the tractor. See
TROUBLESHOOTING on page 100
your
local
KUBOTA
information dealing with electrical problems.
BX1880, BX2380, BX2680
(2) Fuel filter
position for the
About 30 seconds
About 30 seconds
to
follow
the
repairing
ENGINE
or contact
Dealer
for
specific
(1) Fuse box
Protected circuit
[Fuse box]
FUSE no.
Capacity
1
2
3
4
5
6
7
8
9
10
11
12
Slow blow fuse
Capacity
50 A
Check circuit against wrong battery connection
PERIODIC SERVICE
(2) Slow blow fuse
Protected circuit
-
-
-
-
Option (3rd-func-
10 A
tion)
10 A
OPC
15 A
DC outlet
5 A
Fuel pump
-
-
5 A
Glow indicator
5 A
Meter
15 A
Stop solenoid
20 A
Lamp
20 A
Option (work light)
Protected circuit