7 Reference the label on the replacement circuit breaker and set the
circuit breaker in its mounting position with the LINE side of the
breaker facing the input module and the LOAD side of the circuit
breaker facing the AC line filter. Fasten the circuit breaker with the
hardware removed in step 6.
NOTE:
On 120 Vac treadmills connect the blue wire from the input module to the
LINE terminal on the circuit breaker and the blue wire from the AC line filter
to the LOAD terminal on the circuit breaker.
On 240 Vac treadmills connect the blue wire from the input module to the
upper LINE terminal on the circuit breaker and the blue wire from the AC
line filter to the upper LOAD terminal on the circuit breaker. Connect the
brown wire from the input module to the lower LINE terminal on the circuit
breaker and the brown wire from the AC line filter to the lower LOAD
terminal on the circuit breaker.
8 Set the input panel in its mounting position and fasten it with the
hardware removed in step 3.
9 Thoroughly check the treadmill per,
"Section 4 - Operation
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Verification" on page 9).
Checking Treadmill Operation
(see