4.System Wiring and Connections

Basic Connection
Doorbell Button
Switch
Electric Lock Connection
A fail secure (power applied to unlock) electronic lock device should be used.
Note:
1.
Electronic lock of Power-on-to-unlock type should be used.
2.
The door lock is limited to 12V, and holding current must be less than 250mA.
3.
The door lock control is not timed from Exit Button(EB).
4.
The Unlock Mode Parameter of Monitor must be set to 0 (by default).
1 2 3
Jumper position in
BUS
EB
*
Connect one lock
2-3
PL
S+
S-
LOCK
AC~
PC6
BUS(IM) BUS(DS)
-3-
L1 L2 PL S+ S-
-
+