Input the master code.
(Default: [
] +[#] )
1.Reset all settings
Input the setting code.
00+#
The color of key indicator
Beep+, Beep
(yellow)
Inputting of code
1234+#
The color of key indicator
Beep+
(green
white)
- When the "
*
cancel" key is pressed, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
- When there isn't any operation in 10s, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
- When setting failure, the color of key indicator will turn red , the buzzer beeps.
- All settings will restore to their
default value.
- When the keypad is powered on
or the reset function is activated
the keypad will carry out system
check, during this period the key
illumination will flash, DO NOT
TOUCH THE KEYPAD. On
completion the flashing will stop
followed by a long beep.
3
6
9
#
2.Setting the master code
(Default 1234)
Input the setting code.
01+#
The color of key indicator
Beep+, Beep
(yellow)
Inputting of new master code
(ex.: 4321)(1~12 digits)
4321+#
The color of key indicator
Beep+
(green
white)
- The master code can be 1 to 12
digits, the same code cannot be
used for any user code. It is
recommend the default master
code is changed.
Each operation is indicated by the lighting up of the
different color of digital key and nameplate , and by the
sounding of the buzzer.
The color of key indicator
3.Setting the key
illumination time
(Default 10s)
Input the setting code.
02+#
The color of key indicator
Beep+, Beep
(yellow)
Inputting of code (ex.: 10)
range:00 or 10~99
10+#
The color of key indicator
Beep+
(green
white)
- If the key illumination time is set
to 00,the key illumination will light
up all the time when power on.
- If the key illumination time is set to
10~99,the key illumination will light
up for 10~99 seconds. In this mode
the illumination is off, touching any
key will turn the illumination on. Th
illumination will turn off after the set
time if no key is touched or after the
final key press.
-
-
11
(white)
Beep+, Beep
4.Setting the
unlock time
(Default 1s)
Input the setting code.
03+#
The color of key indicator
(yellow)
Inputting of code (ex.: 09)
range:01~99
09+#
The color of key indicator
(green
white)
The color of
key indicator
(The color
of standby)
- The unlock time can be set on
both monitor and door station,
and the valid value is the number
you set last time.
Beep+, Beep
Beep+
Beep, Beep+