Power Outrigger

3
1. Outrigger Select Switch
2. Emergency Stop Switch
Figure 3-4. Power Outriggers
3121303
SECTION 3 - USER RESPONSIBILITIES AND MACHINE CONTROL
1
2
+
3. Battery Isolator
1. Outrigger Select Switch - A three position key operated
switch, allows the operator to select if outriggers are
used or not. The center position will disable the
machine.
2. Emergency Stop Switch - A two-position red mushroom-
shaped emergency stop switch, when positioned to ON
with the power selector switch positioned to ground, fur-
nishes operating power to the ground control station. In
addition, the switch can be used to turn off power to the
function controls in the event of an emergency. Power is
turned on by pulling the switch out (on), and is turned off
by pushing the switch in (off).
3. Battery Isolator Switch - The battery isolator switch is
located outside the battery compartment (chassis).
Rotate handle counterclockwise to disconnect power
rom the battery.