AKD Installation | 6   Technical description and data

6.16.8.3 Functional test

You must test the restart lock function after initial start of the drive, after each inter-
ference into the wiring of the drive, or after exchange of one or several components
of the drive.
First Method:
1. Stop drive, with setpoint 0 V. Keep drive enabled.
DANGER: Do not enter hazardous area!
2. Activate the STO function for example by opening protective screen (voltage at X1/3 0 V).
3. The fault contact opens, the net contactor releases, and the drive displays fault F602.
Second Method:
1. Stop all drives, with setpoint 0 V, disable drive.
2. Activate the STO function, for example, by opening protective screen (voltage at X1/3 0 V)
3. The drive displays warning n602.

6.16.8.4 Mains supply circuit (example)

Corresponding control circuit => p. 55.