Inserting Sequencer Data (Create)
You can insert new sequencer data into a desired location of a phrase
track or pattern.
For details on the sequencer data that can be inserted, refer to
Sequencer Data Handled by a Phrase Track/Pattern (p. 145).
1.
Access the MICROSCOPE screen for the track or pattern
into which you want to insert data (p. 144).
2.
Press [F1 (CREATE)].
The Create Event window appears.
fig.CreateEvent
3.
Press
to select the data that will be inserted.
4.
Press [F6 (EXEC)] to insert the performance data.
The inserted data will have the default parameter values, so edit
them as necessary.
If you are not satisfied with the results of executing this
operation, press [EXIT] to close the MICROSCOPE screen, and
press [ERASE/UNDO] to return to the state prior to execution
(Undo). After executing Undo, you can use Redo to revert to the
previous state by performing the above procedure once again.
Erasing Sequencer Data (Erase)
If desired, you can erase just an individual event of sequencer data.
You can also use the same operation to erase individual items of data
from the tempo track or beat track.
* It is not possible to erase the tempo change located at the beginning of
the tempo track, the beat change located at the beginning of the beat
track, or the pattern beat.
1.
Access the MICROSCOPE screen for the track or pattern
from which you want to erase data (p. 144).
2.
Press
to select the data that you want to erase.
3.
Hold down [SHIFT] and press [F6 (ERASE)] to erase the
sequencer data.
* You can also erase the sequencer data by pressing [ERASE/UNDO] in
the MICROSCOPE screen.
If you are not satisfied with the results of executing this
operation, press [EXIT] to close the MICROSCOPE screen, and
press [ERASE/UNDO] to return to the state prior to execution
(Undo). After executing Undo, you can use Redo to revert to the
previous state by performing the above procedure once again.
Moving Sequencer Data (Move)
You can move an individual item of sequencer data to a different
location. Data recorded in the tempo track or beat track can also be
moved in the same way.
* It is not possible to move the tempo change located at the beginning of
the tempo track, the beat change and key signature located at the
beginning of the beat track, or the pattern beat.
1.
Access the MICROSCOPE screen for the track or pattern
whose data you want to move (p. 144).
2.
Press
to select the data that you want to move.
3.
Press [F2 (MOVE)].
The Move Event window appears.
fig.MoveEvent
4.
Press
to move the cursor to the "Meas (measure),"
"Bt (beat)," and "Tick" fields.
5.
Use the VALUE dial or [INC] [DEC] to specify the location to
which the data will be moved.
6.
Press [F6 (EXEC)] to move the data.
If you are not satisfied with the results of executing this
operation, press [EXIT] to close the MICROSCOPE screen, and
press [ERASE/UNDO] to return to the state prior to execution
(Undo). After executing Undo, you can use Redo to revert to the
previous state by performing the above procedure once again.
Editing Songs