INTERNAL STATIONS

PROGRAMMING

The videointercom must be suitably programmed
for operation.
Two programming modes are available:
-automatic (quick programming of user code
acting from external station);
-manual (programming of all videointercom
functions)
The following programming is possible:
- user address;
- internal address;
- address to assign to button " "; maximum
4 addresses of external door stations;
- code to assign to buttons "1", "2", "3", "4", "5"
and "6" to make intercom calls, door station
monitoring or for special services;
- call timing (max 4 rings) for 4 different call
melodies (see table 2.1);
- selection of the call melody for 4 different
call melodies (see table 2.1).
Factory setting
- user address
= 100
- internal address = 000
- buttons " ", "1", "2", "3", "4", "5", "6" = no
codes are stored to the buttons
- number of call rings and call melody (see
table 2.1)
Table 2.1.
Factory setting for calls
Number Type of
Calls
of rings
from door station
1
intercommunicating
4
from other users
4
floor (local)
1
Attention: it is mandatory to program the
equipment only with the user code (address) all
other programming are optional.
Enter the programming mode
Keep pressed the button
for more than 4
seconds; an acknowledge tone will be shortly
heard while red LED will lights-ON for all
programming phase. If for 2 minutes no keys are
pressed, system switches back to the operating
mode.
Automatic programming
You can use the automatic programming mode
to save the videointercom address from the
external station. To enter the automatic
programming mode you must:
enter the programming mode following the
instructions described in "Enter the
programming mode";
keep pressed the button
4 seconds; red LED starts flashing;
make a call from an external station within
2 minutes. In case of installations with digital
push-button keyboard TD2100, key in the
number you want to assign to the videointercom
and press "
digital encoder CD2131÷CD2138 press the
button you want to assign to the user on the
push-button keyboard. When the call is
received, the videointercom is programmed
automatically, you hear the call tone in the
loudspeaker and the videointercom is turned
on, showing the calling external station. Press
the button
the external door station and verify the correct
working mode of the equipment;
programming mode is signalled on the
external door station by an acknowledge
tone if accepted or a dissuasion tone if
rejected;
repeat programming phases for all the
videointercoms connected to the system.
Manual programming
The manual programming mode allows you to
enter the user address, assign the internal
address and codes to numerical buttons (from
1 to 6) and " ".
Using the push-buttons for programming
Press button "
addresses or codes.
:Press this button to confirm address or
code programming or go to the next
programming step.
: Press this button to confirm the digit just
dialled and to proceed to enter next digit
in the following order: hundreds + , tens
+ , units + .
1 : Press this button to increase the value
melody
you want to enter. Press the button for a
number of times equal to the digit you want
Din-Don
to enter (digit 1 = 1 time; digit 9 = 9 times;
Dring 1
digit 0 = 10 times button "1").
Dring 2
Entering codes or addresses
Dring 3
- Codes and/or addresses must have three
digits (hundreds, tens, units); codes and/or
addresses with tens and units or units only
must be completed by adding zeros. For
example, address 96 will become 096 and
address 5 will become 005.
- Digits must be entered individually (beginning
from the hundred), by pressing the button "1"
for a number of times "n", where "n" is the
value of the digit you want to enter. Store the
digit pressing the button " "; a tone will
confirm the acquisition of the 1
- Follow the same procedure to store the 2nd
and 3rd digit.
For example, to enter code 096 you must:
- press button "1" 10 times to enter digit 0 and
press the button " "; you will get a tone on the
loudspeaker;
- press button "1" 9 times to enter digit 9 and
press the button " "; you will get a tone on the
loudspeaker;
- press button "1" 6 times to enter digit 6 and
press the button " "; you will get a tone on the
for more than
loudspeaker.
Programming of the user address and
internal address
- User address – this code allows you to
receive an external call, turn on the
(MT13 - En 2015)
". In case of installations with
- Internal address – these codes are used
to start the conversation with
To program the user address and internal
address it is necessary to:
", " " and "1" to enter
Note. If one of the two above mentioned
addresses is already correctly programmed
and you don't want to program it again it
would be possible to skip its programming by
simply pressing button
Programming address to be stored to
each button
Button " ". To this button can be stored the
addresses of maximum 4 external stations
which can be connected sequentially. In this
way the user can monitor, communicate or
open the door of 4 different external stations
without being called from them but simply
st
digit.
pressing several times the button
In the case of a system with only 1 external
door station it isn't necessary to store
any address because it will be acquired
automatically at the first call.
To make the programming it necessary to:
2.
25
videointercom, have a conversation and
open the door at the calling external station.
to identify the videointercoms installed in
the apartment (max. 7). In case of one
videointercom only, the internal code must
be 000 (default value); if other videointer-
coms are present (max. other 6) you must
assign to them the codes 001, 002, 003 etc.
Programming these addresses all the
videointercoms will ring-UP when receiving
an external, intercommunicating or floor
(local) call (if programmed - see page 2.27).
enter the programming mode following
the instructions described in "Enter the
programming mode";
keep pressed the button
for more than
4 seconds; red LED starts flashing;
enter the 3 digit of the user address
following the procedure reported on the
paragraph
"Entering
codes
addresses";
press the button
to confirm the present
phase and move to the next phase which is:
programming of the internal address; an
acknowledge tone will be heard;
enter the 3 digit of the internal address
following the procedure reported on the
paragraph
"Entering
codes
addresses";
press the button
to confirm; an ac-
knowledge tone will be heard and the red
LED lights-ON continuously;
proceed with another programming phase
or exit the programming mode pressing
button
or
.
.
enter the programming mode following
the instructions described in "Enter the
programming mode";
keep pressed the button " " for more than
4 seconds; red LED starts flashing;
enter the 3 digit of the address of the 1st
external door station to be stored (codes
from 231 to 250) following the procedure
reported on the paragraph "Entering
codes or addresses" ;
2
or
or
.

Hide quick links: