SERVICE MODULES

BUFFER OF RISER

54
89
/
1
2
"
/
1
3
8
"
2
2231.
The buffer 2231 can be used to create
independent sections within the same DUO
videointercom installation, thus allowing to
have local services without engaging the
main common line.
A few examples are:
- intercom and/or domotic services inside a
single apartment with/without a secondary
entrance;
- intercom and/or domotic services in some
apartments with/without a secondary
entrance;
- connection of a building (with/without
secondary entrance) to one or more main
entrances.
The LED, present in the device, turns on the
switching and for all the time of activation of the
DUO system.
Technical features
Power supply from the line
Stand-by current (LI-LO):
Operating current (LS):
Housing:
3 module A DIN
Operating temperature:
Maximum humidity acceptable:
Fits on DIN bar or with 2 expansion plugs
Terminals
LM - LM Line power supply input
LI - LI
Main DUO line input
LO - LO Main DUO line output
LP - LP Input from secondary door station
LS – LS Secondary DUO line output

PROGRAMMING

Preliminary notes
- To manage videointercom or intercom
addresses connected to the lines LS are
available 10 numerical intervals (F1÷F10). In
each numerical interval can be stored the
address of a single device or the first and the
last address of a group of intercoms/
videointercoms, with sequential addresses,
related to the same line.
For example if in the numerical interval F1 is
stored the address 100, on the line LS only
the calls addressed to the intercom/
videointercom 100 is delivered. Vice-versa if
on the same numerical interval F1 are stored
the addresses 100 and 120, on the line LS
Position of J6's jumper and related function
Operating mode
65
1-2 position
(Red LED flashes slowly)
/
9
2
"
16
are delivered the call addressed to all the
intercoms/videointercoms whose address is
between 100 and 120.
- To enable the secondary door station , if
present in the riser, you need to store, in one
of the 10 numerical intervals, the address of
the door station connected to terminals LP.
Use the other numerical intervals to store the
addresses of any additional door stations
connected to the LP terminals.
- Attention: if during the programming some
error are made or if later it is necessary to
modify some addresses already stored
in the memory of the buffer, it is necessary
to erase the whole memory of the device
executing the "memory erasing" procedure
and than reprogramming completely the de-
vice.
Programming the numerical intervals
To program the numerical intervals F1÷F10 it
is necessary:
1) enter the programming mode moving the
8mA
jumper J6 from position 1-2 to 2-3; the red
40mA
LED flashes quickly;
2) select the numerical interval to be
0° ÷ +50°C
programmed, positioning the micro
90% RH
switches of SW1 according to the
instructions provided in table 4.3 on page
4.10. For example, to program the interval
F1, set to ON micro switch 1 of SW1
leaving OFF micro switches 2, 3 and 4;
3) store the address of the external door station
or internal station by following the procedure
described here below.
- Videointercom Zhero, myLogic: press
the button
.
- Videointercom Echos, Exhito: press the
button
(MT13 - En 2015)
LI LI LO LO
J1
4
3
2
J6
SW1
ON
1
2
3
4
J6
3 2 1
3
2
1
LM
LM
LS
LS
LP
J2 J3
- Intercom Exhito: pick up the handset,
press the button
- Make a call, from secondary door
stations.
In case you wish to program a group of
addresses, store the address with the lowest
value first.
If the final group address also has to be
programmed in the interval, continue with
step 4; if, on the other hand, only one
address needs to be programmed, move
on to step 5.
Notes.
- Proper storage is indicated by the buffer
LED turning off for one second and then
turning back on in flashing mode.
- Possible audio noise signals in this
phase don't notice any anomaly in the
programming.
4) From the internal station, having the user
address with the highest value, store the
address following the procedure of the
selected model. The device acquires the
address of the last internal station belonging
to the group, allowing all the extensions
programmed in interval F1 to connect to the
LS line.
5) Set OFF the microswitch 1 of SW1. This
operation ends the programming phase of
the numerical interval F1
SW1
6) If required, proceed in a similar way to
ON
program the other 9 numerical intervals
1
2
3
4
J6
repeating the instructions reported on points
from 2 to 5 and paying attention to set
LM
LM
LS
LS
LP
LP
J2 J3
properly the microswitches of SW1
according to the numerical interval to be
ON
programmed (see table 4.3 on page 4.10).
ON
7) Set OFF all the microswitches of SW1 and
exit the programming mode moving jumper
J6 from position 2-3 to 1-2; red LED comes
1
2
3
4
back flashing slowly
OFF
8) Verify the correct operations of door stations
and of intercoms/video-intercoms
connected to line LS of the art.2231
4.
9
LED
1
Programming mode
2-3 position
(Red LED flashes quickly)
J6
3
2
1
LP
, hang up the handset
.
4