  • Page 1 ALTERNATE CURRENT CALL SYSTEMS T E C H N I C A L M A N U A L 2 0 0 4...
  • Page 2 In order to make the systems work properly it is necessary to install only foam, etc.) must be kept out of the reach of children. Farfisa equipment, keeping strictly to the items referred to in each diagram. The manufacturer cannot be held responsible for possible damages caused by improper, erroneous and unreasonable use.
  • Page 3 TECHNICAL MANUAL 2004 edition INDEX Page Installation instructions Intercoms - Internal stations - External door stations - Power supplies - Service modules - Installation instructions - Installation diagrams Video Intercoms - Internal stations - External door stations - Power supplies, control units and service modules - Installation instructions - Installation diagrams Telecommunication...
  • Page 4 INSTALLATION INSTRUCTIONS The Farfisa alternate call system allows for the For the realisation of basic video intercom The following options are possible for internal realisation of intercom, video intercom, digital systems you need 7 common wires + 1 single stations: and intercom-telephone systems.
  • Page 5 INTERCOMS Technical manual 12 Edition 2004 INDEX Page Internal stations - Project series intercoms - PuntoVirgola series intercoms - Slim (900) series intercoms External door stations - Mody series push-button panels - Matrix series push-button panels - ErreP/R series push-button panels...
  • Page 6 INTERNAL STATIONS INTERCOMS PROJECT series PT502. Led module. " " PT515. Bell silencer module (privacy). " intercom call push- button PT515 Note PT520. Two-colour intercom for 4+1 systems We recommend to insert the LED module PT502 connected to one or more door stations. Com-...
  • Page 7 PT502 PT515 Two of the following modules can be si- multaneously applied PT538. Table adapter for Project series in- inside the intercoms: tercoms, with weighted base, junction box and - RL36 relay module; 2.4m connection cable with 13 wires. - SM50 private con- versation module;...
  • Page 8 INTERNAL STATIONS INTERCOMS PuntoVirgola series INTERCOMS 900 series (Slim) OPEN VOICE 900 series " " " " " " " " " " PV100. Two-colour intercom for 4+1 systems 924W. Beige intercom for 4+1 systems con- 910W. Open-voice, white, two-way model for connected to one or more door stations.
  • Page 9 EXTERNAL DOOR STATIONS PUSH-BUTTONS MODY series Push-button panels in extruded aluminium made up Module frames complete with back box of modular elements. Suitable for the most diverse " " installation requirements. MD71. 72. 73. 74. Plastic back boxes complete with "...
  • Page 10 EXTERNAL DOOR STATIONS PUSH-BUTTONS MODY series 1 row push-button modules ELECTRIC DOOR SPEAKER 25.5 Modules for electric door speaker (amplifier) " " " MD 10 MD 11 MD 12 without call buttons 1 call button 2 call buttons MD 30. It consists of a double amplifier (receiver and Button modules transmitter) with adjustable volume of 2 chan-...
  • Page 11 EXTERNAL DOOR STATIONS PUSH-BUTTONS MODY series AMPLIFIED DOOR STATIONS ACCESS CONTROL KEYPAD PROXIMITY READER FOR ACCESS CONTROL " " " " " " " " MD 100. 1 button module. FC52P. FP52. Fittable in all intercom, telephone, intercommu- Access control keypad with 12 keys and 2 This article allows for the activation of 2 relays nicating and video intercom systems.
  • Page 12 EXTERNAL DOOR STATIONS PUSH-BUTTONS MODY series " aaaaaaaaaaaaa Openings for cables. Place the box of the push button panel at a height of about 1.65m (5' 5") from the floor keeping the front edges flush-mounted and vertical to the finished plaster. Mounting of button module.
  • Page 13 EXTERNAL DOOR STATIONS PUSH-BUTTONS MODY series Alignment of the panel. Hood covers Mounting of frame bottom and door speaker (amplifier). Modules insertion and wall fixing of rain shelter. Fixing of the hood cover between the back box and the module frame. Rain shelter Top fixing of the panel.
  • Page 14 EXTERNAL DOOR STATIONS 1 row push-button PUSH-BUTTONS MODY series Example of Mody push-button panel installations. 1 call button 2 call buttons 7 call buttons 8 call buttons 9 call buttons 10 call buttons 3 call buttons 4 call buttons 5 call buttons 6 call buttons 11 call buttons 13 call buttons...
  • Page 15 EXTERNAL DOOR STATIONS 1 row push-button PUSH-BUTTONS MODY series Composition board of Mody push-button panels. N° Compositions Door speaker Module for Button modules and Back box and Hood Rain calls and dimensions (amplifier) speaker number or blank module module frame covers shelter 1 MD30...
  • Page 16 EXTERNAL DOOR STATIONS 2 row push-button PUSH-BUTTONS MODY series Example of Mody push-button panel installations. 2 call buttons 4 call buttons 14 call buttons 16 call buttons 18 call buttons 20 call buttons 6 call buttons 8 call buttons 10 call buttons 12 call buttons 22 call buttons 26 call buttons...
  • Page 17 EXTERNAL DOOR STATIONS 2 row push-button PUSH-BUTTONS MODY series Composition board of Mody push-button panels. N° Compositions Door speaker Module for Button modules and Back box and Hood Rain calls and dimensions (amplifier) speaker number or blank module module frame covers shelter 1 MD30...
  • Page 18 EXTERNAL DOOR STATIONS PUSH-BUTTONS Matrix series Stainless steel anti-vandalism push-button Module frames complete with back box panels especially studied to withstand burglary, penetration of solids and water jets (IP 45 protection degree against the penetration of external solids and water; IK09 against shocks). The Matrix push-button panels include back boxes, module frames, die-cast aluminium decorative frames, button modules, and mod-...
  • Page 19 EXTERNAL DOOR STATIONS PUSH-BUTTONS Matrix series Modules with door speaker inte- Push-button modules Audio adjustments grated If necessary, it is possible to adjust the volume of the 2 channels audio opportunely varying the MA 10P. MA 20. external knobs. - amplified speaker unit with volume adjust- Blank module in stanless steel.
  • Page 20 EXTERNAL DOOR STATIONS PUSH-BUTTONS Matrix series Insertion of spacers between back boxes. Spacers and cable bushing (not supplied with the products) must be inserted before brick work. Place the box of the push button panel at a height of about 1.65m (5' 5") from the floor keeping the front edges flush-mounted and vertical to the finished plaster.
  • Page 21 EXTERNAL DOOR STATIONS PUSH-BUTTONS Matrix series Fixing of frame to back box. Align the frame before tightening the screws. For easier connection to the electrical system, it is recommended to insert the metal plate supplied with the product in the back box opening, as shown in the figure.
  • Page 22 EXTERNAL DOOR STATIONS PUSH-BUTTONS Matrix series Example of Matrix push-button panel installations. 6 call buttons 1 call button 2 call buttons 7 call buttons 10 call buttons 8 call buttons 9 call buttons 10 call buttons 3 call buttons 4 call buttons 5 call buttons 6 call buttons 11 call buttons...
  • Page 23 EXTERNAL DOOR STATIONS PUSH-BUTTONS Matrix series Composition board of Matrix push-button panels. Compositions Door speaker Button modules and Front Back box and N° and dimensions module (amplifier) number or blank module frames module frame calls 1 MA11P 1 MA61 1 MA71 140x140x19 "...
  • Page 24 EXTERNAL DOOR STATIONS PUSH-BUTTONS ErreP/R series AMPLIFIED DOOR STATIONS " " " " " " " " R P 8 R P 4 R P 6 R P 2 R P 1 2 R P 1 0 RP100. 1-button amplified door station. RP.
  • Page 25 EXTERNAL DOOR STATIONS PUSH-BUTTONS UP series Surface mounted version Flush mounted version 42.5 " " " " " " UP 100. Amplified push-button panel with 1 call button. UP 11. Amplified push-button panel with 1 call button. Fittable in all 4+1 intercom and intercommunicating systems. Fittable in all 4+1 intercom and intercommunicating systems.
  • Page 26 230V ULE. X Power supply for auxiliary services 12Vdc- 0.2A It may be installed with Project series intercoms Power supply 13Vac for: for supplying power to 4+1 systems with private - name plate lamps, exchangers (continuous conversation module. Only the intercom which load 0.6A)
  • Page 27 SERVICE MODULES " " " " " " " " " 1473. 4-CONTACT ANALOG EXCHANGER. 1471. RELAY UNIT 1472. 2-CONTACT RELAY UNIT It is installed in intercom systems with two or A low voltage, low current (DC/AC) unit, it can Same as 1471, but with 2 relays and 9S input more entrances for switching the audio lines switch voltages up to 50V and 5A max.
  • Page 28 INSTALLATION INSTRUCTIONS General characteristics ELECTRIC DOOR LOCK ACTIVATION - The cable runs of intercom and video intercom installations must be In case of long distances or if you want to control several door locks at the same time, install a relay as shown in the following installation kept separate from the mains or any other electrical installation as diagrams.
  • Page 29 INSTALLATION INSTRUCTIONS WORKING INSTRUCTIONS ADDITIONAL BELL Basic systems If the ringing volume is not sufficient or if you need to chime the call in a For all the intercom systems, simply lift the handset to speak to the door different place, you can add an additional bell enabled by a relay. station.
  • Page 30 TROUBLESHOOTING PRELIMINARY CHECKS - Check for the presence of the mains voltage to restore power, it is necessary to cut off the - Check that the cross section of the cables in the terminals 230Vac (or 127Vac) of the mains voltage for about one minute. Reconnect corresponds to what is indicated on page 26 power supply.
  • Page 31 INSTALLATION DIAGRAMS The following pages show the installation diagrams that are most commonly used in intercom systems. Upon request ACI Farfisa can supply installation diagrams for configurations that are not included in this manual. Systems with 1 or more main entrances...
  • Page 32 Si 11MO/1 INTERCOMS CONNECTED TO 1 EXTERNAL DOOR STATION. Q.ty Article Description PT 510 * Project series intercom with 1 call button Floor call PRS220 Power supply This work diagram allows for differ- PA ** Door release push-button (optional) entiating the floor-call from the call...
  • Page 33 Si 11MO/1 INTERCOMS CONNECTED TO 1 EXTERNAL DOOR STATION (MT12 - Gb2004)
  • Page 34 Si 11MO/2 INTERCOMS WITH PRIVATE CONVERSATION CONNECTED TO 1 EXTERNAL DOOR STATION. Q.ty Article Description PT 510 * Project series intercom with 1 call button Floor call SM 50 Private conversation module This work diagram allows for differ- PRS235 Power supply...
  • Page 35 Si 11MO/2 INTERCOMS WITH PRIVATE CONVERSATION CONNECTED TO 1 EXTERNAL DOOR STATION (MT12 - Gb2004)
  • Page 36 Si 12MO/1 INTERCOMS CONNECTED TO 2 AUTOMATICALLY SWITCHED EXTERNAL DOOR STATIONS. Q.ty Article Description PT 510 * Project series intercom with 1 call button Floor call PRS220 Power supply This work diagram allows for differ- 1473 Exchanger entiating the floor-call from the call...
  • Page 37 Si 12MO/1 INTERCOMS CONNECTED TO 2 AUTOMATICALLY SWITCHED EXTERNAL DOOR STATIONS (MT12 - Gb2004)
  • Page 38 Si 13MO/1 INTERCOMS CONNECTED TO 3 AUTOMATICALLY SWITCHED EXTERNAL DOOR STATIONS. Q.ty Article Description PT 510 * Project series intercom with 1 call button Floor call PRS220 Power supply This work diagram allows for differ- 1473 Exchanger entiating the floor-call from the call...
  • Page 39 Si 13MO/1 INTERCOMS CONNECTED TO 3 AUTOMATICALLY SWITCHED EXTERNAL DOOR STATIONS (MT12 - Gb2004)
  • Page 40 Si 16MO/1 INTERCOM SYSTEM WITH SECONDARY DOOR STATIONS AND 1 MAIN COMMON STATION (multiple entrance) Q.ty Article Description PT 510 * Project series intercom with 1 call button Floor call PRS220 Power supply This work diagram allows for differ- 1473...
  • Page 41 Si 16MO/1 INTERCOM SYSTEM WITH SECONDARY DOOR STATIONS AND 1 MAIN COMMON STATION (multiple entrance) (MT12 - Gb2004)
  • Page 42 Si 16MO/2 ONE-WAY INTERCOM SYSTEM WITH SECONDARY DOOR STATIONS AND 1 MAIN COMMON STATION (multiple entrance) Q.ty Article Description PT 510 * Project series intercom with 1 call button Application of Matrix push- PRS220 Power supply button panel 1473 Exchanger...
  • Page 43 Si 16MO/2 ONE-WAY INTERCOM SYSTEM WITH SECONDARY DOOR STATIONS AND 1 MAIN COMMON STATION (multiple entrance) (MT12 - Gb2004)
  • Page 44 Si 17MO/1 INTERCOM SYSTEM WITH SECONDARY DOOR STATIONS AND 2 MAIN COMMON STATIONS (multiple entrance) Q.ty Article Description PT 510 * Project series intercom with 1 call button Floor call PRS220 Power supply This work diagram allows for differ- 1473...
  • Page 45 Si 17MO/1 INTERCOM SYSTEM WITH SECONDARY DOOR STATIONS AND 2 MAIN COMMON STATIONS (multiple entrance) (MT12 - Gb2004)
  • Page 46 Si 100L/2 2 INTERCOMMUNICATING INTERCOMS Q.ty Article Description PT524 * Project series intercom with 1 call button PRS220 Power supply PT 520 PT 520 CT 1 CT 2 PT 524 PT 524 * Besides the mentioned model the intercom PT520 and PT520W can be installed.
  • Page 47 Si 100L/2 Si 100L/11 2 INTERCOMMUNICATING INTERCOMS INTERCOMMUNICATING INTERCOMS (2 to 11 users) (MT12 - Gb2004)
  • Page 48 * Rain shelters are used instead of back boxes and hood covers. In all intercoms connect one ** Articles not supplied by ACI Farfisa. of the two terminals of the sin- gle button unit to terminal 7. Working instructions. See page 27...
  • Page 49 Si 115L/5S 5 INTERCOMMUNICATING INTERCOMS CONNECTED TO 1 EXTERNAL DOOR STATION WITH SINGLE CALLS. ELECTRONIC BELL FOR INTERNAL CALLS (MT12 - Gb2004)
  • Page 50 Front frame ... Refers to number of users (see table). * Rain shelters are used instead of back boxes and hood covers. ** Articles not supplied by ACI Farfisa. Working instructions. See page 27 In all intercoms connect one Notes...
  • Page 51 Si 111L/5M 5 INTERCOMMUNICATING INTERCOMS CONNECTED TO 1 EXTERNAL DOOR STATION WITH COMMON CALL. ELECTRONIC BELL FOR INTERNAL CALLS SR40 PT520+ PT520+ PT520+ PT520+ PT520+ PT501+ PT501+ PT501+ PT501+ PT501+ SR40 SR40 SR40 SR40 SR40 PRS226 C+ D Mody Matrix MD71 MA71 MD11...
  • Page 52 In all intercoms connect one hood covers. of the two terminals of the sin- ** Articles not supplied by ACI Farfisa. gle button unit to terminal 7. Working instructions Table for choosing intercoms and accessories for the required type of...
  • Page 53 Si 125L/5S 5 INTERCOMMUNICATING INTERCOMS CONNECTED TO 2 EXTERNAL DOOR STATIONS WITH SINGLE CALLS. ELECTRONIC BELL FOR INTERNAL CALLS (MT12 - Gb2004)
  • Page 54 ... Refers to number of users (see table). * Rain shelters are used instead of back boxes and hood covers. ** Articles not supplied by ACI Farfisa. In all intercoms connect one Working instructions of the two terminals of the sin- As the basic system described on page 27, with the gle button unit to terminal 7.
  • Page 55 Si 121L/5M 5 INTERCOMMUNICATING INTERCOMS CONNECTED TO 2 EXTERNAL DOOR STATIONS WITH COMMON CALL. ELECTRONIC BELL FOR INTERNAL CALLS (MT12 - Gb2004)
  • Page 56 7. ** Articles not supplied by ACI Farfisa. Working instructions Table for choosing intercoms and accessories for the required type of As the basic system described on page 27, with the...
  • Page 57 Si 135L/5S 5 INTERCOMMUNICATING INTERCOMS CONNECTED TO 3 EXTERNAL DOOR STATIONS WITH SINGLE CALLS. ELECTRONIC BELL FOR INTERNAL CALLS (MT12 - Gb2004)
  • Page 58 ... Refers to number of users (see table). * Rain shelters are used instead of back boxes and hood covers. ** Articles not supplied by ACI Farfisa. In all intercoms connect one Working instructions of the two terminals of the sin- As the basic system described on page 27, with the gle button unit to terminal 7.
  • Page 59 Si 131L/5M 5 INTERCOMMUNICATING INTERCOMS CONNECTED TO 3 EXTERNAL DOOR STATIONS WITH COMMON CALL. ELECTRONIC BELL FOR INTERNAL CALLS (MT12 - Gb2004)
  • Page 60 Table for choosing intercoms and accessories X Refers to the number of stairways. for the required type of installation * Rain shelters are used instead of back boxes and hood covers. ** Articles not supplied by ACI Farfisa. Number of inter- Project Working instructions.
  • Page 61 Si 161L/1 ONE-WAY INTERCOMMUNICATING SYSTEM WITH SECONDARY DOOR STATIONS AND 1 MAIN COMMON STATION (multiple entrance) (MT12 - Gb2004)
  • Page 62 MULTI-WAY INTERCOM SYSTEM CONNECTED TO 1 EXTERNAL DOOR STATION. With intercommunication service in 1 or more apartments and private conversation feature with the external door station and the other apartments. Q.ty Article Description PT 510 * Project series intercom with 1 call button PRS220 Power supply PA ** Door release push-button (optional) SE ** Electric door lock (12VAC-1A) Door station series Mody (for right item set see on pages 12÷15)
  • Page 63 Si 11MO/3 MULTI-WAY INTERCOM SYSTEM CONNECTED TO 1 EXTERNAL DOOR STATION. With intercommunication service in 1 or more apartments and private conversation feature with the external door station and the other apartments. (MT12 - Gb2004)
  • Page 64 Application diagrams multi-way intercommunicating services ADDITIONAL DIAGRAMS FOR INTERCOMMUNICATING SYSTEMS WITH SINGLE EXTERNAL CALL. BOTH CALLS ACTIVATE THE BUZZER. - To match with diagrams: Si 115L/5S; Si 125L/5S; Si 135L/5S 2 INTERCOMMUNICATING INTERCOMS 3 INTERCOMMUNICATING INTERCOMS to power supply to power supply In all intercoms connect one of the two terminals of the single button unit to terminal 7.
  • Page 65 Application diagrams multi-way intercommunicating services 5 INTERCOMMUNICATING INTERCOMS to power supply In all intercoms connect one of the two In each intercom to cut the jumper terminals of the single button unit to termi- PT 520 (W1) that links terminals 3 and 7 nal 7.
  • Page 66 Application diagrams multi-way intercommunicating services APPLICATION DIAGRAMS FOR INTERCOMMUNICATING SYSTEMS WITH SINGLE ALTERNATE CURRENT CALL FROM EXTER- NAL STATION AND ELECTRONIC CALL FOR EXTENSIONS - To match with diagrams: Si 115L/5S; Si 125L/5S; Si 135L/5S 2 INTERCOMMUNICATING INTERCOMS 3 INTERCOMMUNICATING INTERCOMS to power supply to power supply In intercoms cut the jumper W1 which connects terminals 3 and 7...
  • Page 67 Application diagrams multi-way intercommunicating services 6 INTERCOMMUNICATING INTERCOMS to power supply In intercoms cut the jumper W1 which connects terminals 3 and 7 and apply the electronic buzzer SR40 or SR41 (for the application see the drawings on the page that illustrates the electrical diagram to be realised).
  • Page 68 Application diagrams one-way intercommunicating services APPLICATION DIAGRAMS FOR INTERCOMMUNICATING SYSTEMS WITH COMMON ALTERNATE CURRENT CALL FROM EXTER- NAL STATION AND ELECTRONIC CALL FOR EXTENSIONS - To match with diagrams: Si 111L/5M; Si 121L/5M; Si 131L/5M 2 INTERCOMMUNICATING INTERCOMS 3 INTERCOMMUNICATING INTERCOMS SR40 SR40 PT520+...
  • Page 69 Application diagrams one-way intercommunicating services PRS210 1471 6 INTERCOMMUNICATING INTERCOMS 230V 127V SR40 PT520+ PT520+ PT520+ PT520+ PT520+ PT520+ PT501+ PT501+ PT501+ PT501+ PT501+ PT501+ SR40 SR40 SR40 SR40 SR40 SR40 to power supply In intercoms cut the jumper W1 which connects terminals 3 and 7 and apply the electronic buzzer SR40 or SR41 (for the application see the drawings on the page that illustrates the electrical diagram to be realised).
  • Page 70 Application diagrams one-way intercommunicating services in apartment building system APPLICATION DIAGRAMS FOR ONE-WAY INTERCOMMUNICATING SERVICES IN APARTMENT BUILDING SYSTEMS. ALTERNATE CURRENT CALL FROM THE DOOR STATION AND ELECTRONIC FOR EXTENSIONS - To match with diagrams: Si11MO/1; Si11MO/2; Si12MO/1; Si13MO/1; Si16MO/1; Si17MO/1 (example of application on page 61- Si11MO/3). 2 INTERCOMMUNICATING INTERCOMS to riser - In every intercommunicating intercom ap-...
  • Page 71 Application diagrams one-way intercommunicating services in apartment building system 4 INTERCOMMUNICATING INTERCOMS to riser - In every intercommunicating intercom ap- ply the single button group by connecting one of the two button terminals to terminal 7 of the power supply PRS226E. - Do not use button no.
  • Page 72 Application diagrams one-way intercommunicating services in apartment building system 6 INTERCOMMUNICATING INTERCOMS to riser - In every intercommunicating intercom ap- ply the single button group by connecting one of the two button terminals to terminal 7 of the power supply PRS226E. - Do not use button no.
  • Page 73 VIDEOINTERCOMS Technical manual 12 Edition 2004 INDEX Page Internal stations - Project series videointercoms - PuntoVirgola series videointercoms External door stations - Mody series push-button panels - Matrix series push-button panels Power supply and control units Service modules Installation instructions...
  • Page 74 INTERNAL STATIONS Videointercoms Project series Wall-brackets for the PT5160, PT5160W and PT5160W-LCD videointercoms 215.5 WB5100. The wall bracket includes a WB5160. The wall bracket includes 2 terminal " " terminal board for connection to the sys- boards for connection to the system, it is to be...
  • Page 75 INTERNAL STATIONS Videointercoms Project series Installation of the wall bracket WB5100 or WB5160 to the wall, using a 83.5mm back box and one expansion plugs. Installation of the wall bracket WB5100 or WB5160 to the wall, by means of expansion...
  • Page 76 INTERNAL STATIONS Videointercoms Project series Wall-brackets for the PT5660W videointercoms. " " " WB5600. The wall bracket includes a WB5660. The wall bracket includes 2 terminal terminal board for connection to the sys- boards for connection to the system, it is to be...
  • Page 77 INTERNAL STATIONS Videointercoms Project series 1283. Back-box for videointercoms PT5660W and PV1260. Place the box on the wall at a height of about 1.5m (4' 11") from the floor keeping the front edges flush-mounted and vertical to the fin- ished plaster.
  • Page 78 INTERNAL STATIONS Videointercoms Project series Wall-brackets for the PT5860 and PT5860W videointercoms. " " WB5600. The wall bracket includes a WB5660. The wall bracket includes 2 terminal terminal board for connection to the sys- boards for connection to the system, it is to be...
  • Page 79 INTERNAL STATIONS Videointercoms Project series Plugging in of videointercom connectors to the terminal boards of wall bracket. Installation of videointercom onto the wall bracket. Supplementary push-buttons installation Dismounting of videointercom from the wall bracket. Audio privacy or intercommunicating service Taking out of button caps.
  • Page 80 INTERNAL STATIONS Videointercoms PuntoVirgola series Wall-brackets for the PV2160 and PV2160W videointercoms. " 3 " WB2100. The wall bracket includes a WB2160. The wall bracket includes 2 terminal terminal board for connection to the sys- boards for connection to the system, it is to be tem, it is to be used when installing 2 - used when installing videointercoms with extra button videointercoms (control switch-...
  • Page 81 INTERNAL STATIONS Videointercoms PuntoVirgola Videointercoms PuntoVirgola series series " " " " " PV1260. Two-colour videointercom with tradi- Plugging in of videointercom connectors to the terminal boards tional cathode tube with audio-video privacy, of wall bracket. electronic microphone, differentiated double electronic ringing sounds (modulated and a continuous note) and terminal board for the connection to the wall-bracket.
  • Page 82 INTERNAL STATIONS Videointercoms PuntoVirgola Wall-brackets for the PV1260 video- intercom. 1283. Back-box for PV1260 and PT5660W WB1200. The wall bracket includes a terminal videointercoms. board for connection to the system, it is to be Place the box on the wall at a height of about used when installing 2 - button videointercoms 1.5m (4' 11") from the floor keeping the front (control switch-ON and door lock release), with...
  • Page 83 EXTERNAL DOOR STATIONS PUSH-BUTTON PANELS For information on characteristics and assem- ers, back boxes, rain shelters, hood covers and page 11. bly of push-button panels, electric door speak- modules see section “intercoms” on page 7 to CAMERAS Installation Adjustments If necessary, you can manually modify the cam- "...
  • Page 84 EXTERNAL DOOR STATIONS 1 row push-button MODY series Examples of compositions of Mody push-button panels in video intercom systems push-button panels 1 call button 2 call buttons 3 call buttons 4 call buttons 5 call buttons 6 call buttons 7 call buttons 8 call buttons 10 call buttons 7 call buttons...
  • Page 85 EXTERNAL DOOR STATIONS 1 row push-button MODY series push-button panels Composition board of Mody push-button panels. N° Compositions and Camera Door speaker Module for Button and info or Back box and Hood Rain calls dimensions module (amplifier) speaker blank modules module frame covers shelter...
  • Page 86 EXTERNAL DOOR STATIONS 2 row push-button MODY series Examples of compositions of Mody push-button panels in video intercom systems push-button panels 2 call buttons 4 call buttons 6 call buttons 8 call buttons 10 call buttons 12 call buttons 14 call buttons 16 call buttons 20 call buttons 18 call buttons 14 call buttons...
  • Page 87 EXTERNAL DOOR STATIONS 2 row push-button MODY series push-button panels Composition board of Mody push-button panels. N° Compositions and Camera Door speaker Module for Button and info or Back box and Hood Rain calls dimensions module (amplifier) speaker blank modules module frame covers shelter...
  • Page 88 EXTERNAL DOOR STATIONS MATRIX series push-button panels Installation Video modules with integrated audio amplifier Adjustments You can manually change the camera framing by unloosening and adjusting the horizontal and vertical screws in the desired direction. (±15°) MA 42. Modules complete with: - CCD camera with autoiris, fixed 3.6mm lens and 6 infrared LED’s.
  • Page 89 EXTERNAL DOOR STATIONS MATRIX series push-button panels Flush mounting and Fixing of frame to back box. cables placing. Align the frame before tightening the screws. Mounting of button module. For easier connec- tion to the electrical system, it is recom- mended to insert the metal plate supplied with the product in...
  • Page 90 EXTERNAL DOOR STATIONS MATRIX series push-button panels Examples of compositions in video intercom systems 5 call buttons 1 call button 3 call buttons 7 call buttons 6 call buttons 8 call buttons 9 call buttons 9 call buttons 2 call buttons 3 call buttons 4 call buttons 5 call buttons...
  • Page 91 EXTERNAL DOOR STATIONS MATRIX series push-button panels Composition board of Matrix push-button panels. Compositions and Camera module Button and info or Front Back box and N° dimensions and door speaker blank modules frame module frame calls 140x140x19 1 MA43 1 MA61 1 MA71 "...
  • Page 92 POWER SUPPLY AND CONTROL UNIT SERVICE MODULES " " " 107.5 " " " " " " 1281. STABILIZED POWER SUPPLY WITH 1382. AUDIO-VIDEO TIMER. 2443. AMPLIFIER-SWITCHER FOR INTER- SWITCHING REGULATOR. COMMUNICATING SYSTEMS. Connected to the stabilized power supply It is suitable for video intercom systems where Connected to the timer art.1382, allows to drive art.1281, it allows a videointercom system to it is necessary to have the intercommunicating...
  • Page 93 SERVICE MODULES INSTALLATION INSTRUCTIONS General characteristics - The cable runs of intercom and video intercom installations must be kept separate from the mains or any other electrical installation as required by " " the International Safety Standards and the entire installation must be realized in compliance with the safety rules in force in any specific Coun- try.
  • Page 94 INSTALLATION INSTRUCTIONS WIRE CROSS-SECTION Terminals Distance 1304. MULTI-CORE CABLE 4 . 9 . 11 . 12 . 13 . H F . 14 . A . S Video intercom cable with 10 wires of 1 . 2 . 3 . D . 10 (call) (wires in bold face type) different cross-sections and 75Ω...
  • Page 95 INSTALLATION INSTRUCTIONS Technical data 476. VIDEO DISTRIBUTOR-AMPLIFIER. Power supply 21 ± 3Vdc Terminals It allows for the distribution of the video signal Operating current at max. load 250mA General ground coming from the cameras on 5 independent Gain at max. load from 0 to 3.5dB (adjustable) Positive power supply lines.
  • Page 96 WORKING INSTRUCTIONS TROUBLESHOOTING Check that the connections of the system The probability of breakdown in the video-intercom The electric door lock does not function. systems is obviously greater than in the intercom Faulty lock. The cross section of the wires indi- are carried out correctly.
  • Page 97 INSTALLATION DIAGRAMS The following pages show the installation diagrams that are most commonly used in videointercom systems. Upon request ACI Farfisa can supply installation diagrams for configurations that are not included in this manual. Systems with 1 or more main entrances...
  • Page 98 Black 0.35 Green 0.35 * The rain shelter is used in the place of the back box and hood cover. Orange 0.35 ** Articles not supplied by ACI Farfisa. White 0.25 Pink 0.25 Working instructions. See page 94. Light blue 0.25...
  • Page 99 Si 311O/14 One-way video intercom system with long distance between video intercom and main power supply 1281 RL37 230V 127V MD41 MD72 MD11 MD30 1382 PV1260+ PT5660+ PT5160+ 1283+ 1283+ WB5100 WB1200 PV2160+ The following articles must be added to the list on WB5600 WB2100 PT5860+...
  • Page 100 ... Refers to number of users. * The rain shelter is used in the place of the back box and hood cover. ** Articles not supplied by ACI Farfisa. Application of MD100 and MD200 modules in one and multiway systems Working instructions.
  • Page 101 Si 31MO/1 VIDEO INTERCOM SYSTEM CONNECTED TO ONE EXTERNAL DOOR STATION coax (MT12 - Gb2004)
  • Page 102 ... Refers to number of users. * The rain shelter is used in the place of the back box and hood cover. ** Articles not supplied by ACI Farfisa. Working instructions Application of MD100 and MD200 modules...
  • Page 103 Si 31MC/1 MIXED INTERCOM AND VIDEO INTERCOM SYSTEM CONNECTED TO ONE EXTERNAL DOOR STATION Intercom without private conversation Intercom with private conversation coax (MT12 - Gb2004)
  • Page 104 ... Refers to number of users. * The rain shelter is used in the place of the back box and hood cover. ** Articles not supplied by ACI Farfisa. Working instructions. See page 94. Notes - If the control switching ON is necessary, con- nect terminal 4 of the timer (dashed wire).
  • Page 105 Si 31MO/2 VIDEO INTERCOM SYSTEM CONNECTED TO ONE EXTERNAL DOOR STATION WITH SURVEILLANCE CAMERA coax (MT12 - Gb2004)
  • Page 106 Back boxes and module frames ... Refers to number of users. * The rain shelter is used in the place of the back box and hood cover. ** Articles not supplied by ACI Farfisa. Notes Control switching ON deactivation - To have the control switch ON for the 2 video...
  • Page 107 Si 32MO/1 VIDEO INTERCOM SYSTEM CONNECTED TO TWO EXTERNAL DOOR STATIONS coax (MT12 - Gb2004)
  • Page 108 * The rain shelter is used in the place of the back box and hood cover. Control switching ON deactivation ** Articles not supplied by ACI Farfisa. To activate the control switching ON from the videointercoms only when the system is in standby,...
  • Page 109 Si 32MO/2 VIDEO INTERCOM SYSTEM CONNECTED TO TWO EXTERNAL DOOR STATIONS, ONE OF WHICH ONLY AUDIO coax (MT12 - Gb2004)
  • Page 110 ... Refers to number of users. * The rain shelter is used in the place of the back box and hood cover. ** Articles not supplied by ACI Farfisa. Notes - To have the control switch ON for the 3 video...
  • Page 111 Si 33MO/1 VIDEO INTERCOM SYSTEM CONNECTED TO THREE EXTERNAL DOOR STATIONS coax (MT12 - Gb2004)
  • Page 112 * The rain shelter is used in the place of the back box and hood cover. Control switching ON deactivation ** Articles not supplied by ACI Farfisa. To activate the control switching ON from the videointercoms only when the system is in...
  • Page 113 Si 33MO/2 VIDEO INTERCOM SYSTEM CONNECTED TO THREE EXTERNAL DOOR STATIONS, ONE OF WHICH ONLY AUDIO coax (MT12 - Gb2004)
  • Page 114 * The rain shelter is used in the place of the back box and hood cover. Control switching ON deactivation ** Articles not supplied by ACI Farfisa. To activate the control switching ON from the videointercoms only when the system is in standby,...
  • Page 115 Si 33MO/7 VIDEO INTERCOM SYSTEM CONNECTED TO THREE EXTERNAL DOOR STATIONS, TWO OF WHICH ONLY AUDIO coax (MT12 - Gb2004)
  • Page 116 ... Refers to number of users. X Refers to number of secondary door stations. * The rain shelter is used in the place of the back box and hood cover. ** Articles not supplied by ACI Farfisa. The main entrance push-button panel Notes Working instructions must have separate common terminals.
  • Page 117 Si 36MO/2 VIDEO INTERCOM SYSTEM WITH SECONDARY VIDEO STATIONS AND 1 MAIN COMMON VIDEO STATION (multiple entrance) Application of Matrix push-button panel The button common terminal of every module CANNOT be separated. For the composition of the push-button panel at the main entrance, carefully select the button modules in order to obtain the...
  • Page 118 ... Refers to number of users. X Refers to number of secondary door stations. * The rain shelter is used in the place of the back box and hood cover. ** Articles not supplied by ACI Farfisa. The main entrance push-button panel Working instructions Notes must have separate common terminals.
  • Page 119 Si 36MO/3 VIDEO INTERCOM SYSTEM WITH SECONDARY DOOR STATIONS ONLY AUDIO AND 1 MAIN COMMON VIDEO STATION (multiple entrance) Application of Matrix push-button panel The button common terminal of every module CANNOT be separated. For the composition of the push-button panel at the main entrance, carefully select the button modules in order to obtain the...
  • Page 120 ... Refers to number of users. X Refers to number of secondary door stations. * The rain shelter is used in the place of the back box and hood cover. ** Articles not supplied by ACI Farfisa. The main entrance push-button panel Working instructions must have separate common terminals.
  • Page 121 Si 36MO/4 VIDEO INTERCOM SYSTEM WITH SECONDARY VIDEO STATIONS AND 1 MAIN COMMON STATION ONLY AUDIO (multiple entrance) Application of Matrix push-button panel The button common terminal of every module CANNOT be separated. For the composition of the push-button panel at the main entrance, carefully select the button modules in order to obtain the...
  • Page 122 X Refers to number of secondary door stations. 1473 * The rain shelter is used in the place of the back box and hood cover. ** Articles not supplied by ACI Farfisa. Working instructions Connection of the MD100 amplified external door station to the...
  • Page 123 Si 36MO/5 VIDEO INTERCOM SYSTEM WITH ONE-WAY SECONDARY DOOR STATIONS ONLY AUDIO AND 1 MAIN COMMON VIDEO STATION (multiple entrance) Application of Matrix push- button panel Connect all the common "C" ter- minals of the modules gether. coax (MT12 - Gb2004)
  • Page 124 One common terminal for each secondary ** Articles not supplied by ACI Farfisa. Working instructions door station. Buttons of the Mody series can It is similar to the basic system described on be divided into 2-button groups.
  • Page 125 Si 37MO/1 VIDEO INTERCOM SYSTEM WITH SECONDARY VIDEO STATIONS AND 2 MAIN COMMON VIDEO STATIONS (multiple entrance) coax (MT12 - Gb2004)
  • Page 126 Additional diagrams EXTENSION OF VIDEO INTERCOM SYSTEMS All installation diagrams in this technical manual are drawn with only one video intercom for each user. It is possible to “personalise” the installation by properly matching the applications on the following pages (page 126 to 148) to the basic diagrams (page 99 to page 123). Such examples refer to applications with one video intercom entrance.
  • Page 127 Additional diagrams EXTENSION OF VIDEO INTERCOM SYSTEMS Extension of ONE-WAY system Extension in one apartment of a MULTI-WAY system To realise a one-way system with several monitors and/or To realise a multi-way system with several video intercoms and/or intercoms in intercoms in parallel, with or without intercommunicating parallel in one apartment with or without intercommunicating service, you service, you must proceed as follows:...
  • Page 128 ONE-WAY additional diagrams 1 VIDEO INTERCOM AND 1 INTERCOM WITH INTERCOMMUNI- 2 INTERCOMMUNICATING VIDEO INTERCOMS CATING SERVICE to terminal I of 1382 X1 to be connected to terminal A of art.1382 Read notes 1abc, 2 and 4 of page 124. Read notes 1abc, 3 and 4 of page 124.
  • Page 129 ONE-WAY additional diagrams 3 INTERCOMMUNICATING VIDEO INTERCOMS 1 VIDEO INTERCOM AND 3 INTERCOMS WITH INTERCOMMUNI- CATING SERVICE to terminal I of 1382 X1 to be connected to terminal A of art.1382 Read notes 1abc, 2, 3 and 4 of page 124. Read notes 1abc, 2 and 4 of page 124.
  • Page 130 ONE-WAY additional diagrams 4 INTERCOMMUNICATING VIDEO INTERCOMS VC = or, if intercommunicating PT5160 + WB5100 PT5160 + WB5160 PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 Read notes 1abc, 3 and 4 of page 124. PT5860 + WB5600 PT5860 + WB5660 PV2160 + WB2100 PV2160 + WB2160...
  • Page 131 ONE-WAY additional diagrams 2 VIDEO INTERCOMS AND 3 INTERCOMS WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 Read notes 1abc, 2, 3 and 4 of page 124. PT5860 + WB5600 PT5860 + WB5660 PV2160 + WB2100...
  • Page 132 ONE-WAY additional diagrams 4 VIDEO INTERCOMS AND 1 INTERCOM WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 Read notes 1abc, 2, 3 and 4 of page 124. PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 PT5860 + WB5600...
  • Page 133 ONE-WAY additional diagrams 1 VIDEO INTERCOM AND 5 INTERCOMS WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 PT5860 + WB5600 PT5860 + WB5660 Read notes 1abc, 2 and 4 of page 124.
  • Page 134 ONE-WAY additional diagrams 3 VIDEO INTERCOMS AND 3 INTERCOMS WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 Read notes 1abc, 2, 3 and 4 of page 124. PT5860 + WB5600 PT5860 + WB5660 PV2160 + WB2100...
  • Page 135 ONE-WAY additional diagrams 5 VIDEO INTERCOMS AND 1 INTERCOM WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 Read notes 1abc, 2, 3 and 4 of page 124. PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 PT5860 + WB5600...
  • Page 136 ONE-WAY additional diagrams 1 VIDEO INTERCOM AND 6 INTERCOMS WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 Read notes 1abc and 2 of page 124. PT5860 + WB5600 PT5860 + WB5660 PV2160 + WB2100...
  • Page 137 ONE-WAY additional diagrams 3 VIDEO INTERCOMS AND 4 INTERCOMS WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 Read notes 1abc and 2 of page 124. PT5860 + WB5600 PT5860 + WB5660 PV2160 + WB2100...
  • Page 138 ONE-WAY additional diagrams 5 VIDEO INTERCOMS AND 2 INTERCOMS WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 PT5860 + WB5600 PT5860 + WB5660 Read notes 1abc, 2 and 3 of page 124.
  • Page 139 MULTI-WAY additional diagrams 1 VIDEO INTERCOM AND 1 INTERCOM WITH INTERCOMMUNI- 2 INTERCOMMUNICATING VIDEO INTERCOMS CATING SERVICE D = 100V-1A diode (type 1N4007) D = 100V-1A diode (type 1N4007) Read notes 1ac, 3, 4 and 5 of page 124. Read notes 1ac, 2, 4 and 5 of page 124. 1 VIDEO INTERCOM AND 2 INTERCOMS WITH INTERCOMMU- 2 VIDEO INTERCOMS AND 1 INTERCOM WITH INTERCOM- NICATING SERVICE...
  • Page 140 MULTI-WAY additional diagrams 3 INTERCOMMUNICATING VIDEO INTERCOMS VC = or, if intercommunicating PT5160 + WB5100 PT5160 + WB5160 PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PT5860 + WB5600 PT5860 + WB5660 PV2160 + WB2100 PV2160 + WB2160 PV1260 + WB1200 + 1283 PV1260 + WB1260 + 1283 D = 100V-1A diode (type 1N4007)
  • Page 141 MULTI-WAY additional diagrams 2 VIDEO INTERCOMS AND 2 INTERCOMS WITH INTERCOMMUNICATING SERVICE D = 100V-1A diode (type 1N4007) VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 Read notes 1ac, 2, 3, 4 and 5 of page 124. PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100...
  • Page 142 MULTI-WAY additional diagrams 4 INTERCOMMUNICATING VIDEO INTERCOMS D = 100V-1A diode (type 1N4007) VC = or, if intercommunicating PT5160 + WB5100 PT5160 + WB5160 Read notes 1ac, 2, 3, 4 and 5 of page 124. PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PT5860 + WB5600 PT5860 + WB5660...
  • Page 143 MULTI-WAY additional diagrams 2 VIDEO INTERCOMS AND 3 INTERCOMS WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 D = 100V-1A diode (type 1N4007) PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 PT5860 + WB5600 PT5860 + WB5660...
  • Page 144 MULTI-WAY additional diagrams 4 VIDEO INTERCOMS AND 1 INTERCOM WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 D = 100V-1A diode (type 1N4007) PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 PT5860 + WB5600 PT5860 + WB5660...
  • Page 145 MULTI-WAY additional diagrams 1 VIDEO INTERCOM AND 5 INTERCOMS WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 D = 100V-1A diode (type 1N4007) PT5860 + WB5600 PT5860 + WB5660 PV2160 + WB2100...
  • Page 146 MULTI-WAY additional diagrams 3 VIDEO INTERCOMS AND 3 INTERCOMS WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 D = 100V-1A diode (type 1N4007) PV100 PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PT5860 + WB5600 PT5860 + WB5660 Read notes 1ac, 2, 3, 4 and 5 of page 124.
  • Page 147 MULTI-WAY additional diagrams 5 VIDEO INTERCOMS AND 1 INTERCOM WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 D = 100V-1A diode (type 1N4007) PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 PT5860 + WB5600 PT5860 + WB5660...
  • Page 148 MULTI-WAY additional diagrams 1 VIDEO INTERCOM AND 6 INTERCOMS WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 D = 100V-1A diode (type 1N4007) PT5860 + WB5600 PT5860 + WB5660 PV2160 + WB2100...
  • Page 149 MULTI-WAY additional diagrams 3 VIDEO INTERCOMS AND 4 INTERCOMS WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = D = 100V-1A diode (type 1N4007) PT5160 + WB5100 PT5160 + WB5160 PT510 PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 Read notes 1ac, 2, 3 and 5 of page 124.
  • Page 150 MULTI-WAY additional diagrams 5 VIDEO INTERCOMS AND 2 INTERCOMS WITH INTERCOMMUNICATING SERVICE VC = or, if intercommunicating CT = PT5160 + WB5100 PT5160 + WB5160 PT510 PT5660 + WB5600 + 1283 PT5660 + WB5660 + 1283 PV100 PT5860 + WB5600 PT5860 + WB5660 D = 100V-1A diode (type 1N4007) PV2160 + WB2100...
  • Page 151 The main intercom and video intercom functions can also be provided with an ordinary telephone set by installing a suitable interface in the intercom system. For better intercom/telephone integration it is advisable to use the dedicated Farfisa telephone art. ST740W. In addition to the normal telephone functions, this telephone has extra buttons for intuitive and easy use of intercom functions.
  • Page 152 INTERNAL STATIONS TELEPHONE FIXING ELEMENTS " " WB 700. Bracket for fixing on wall or to table adapter (with art.TA700) the ST740 telephone and/or accessories of the Studio series. Complete with plastic templates for the cor- rect alignment with bracket WB 7100 and/or other brackets WB700.
  • Page 153 INTERNAL STATIONS Table version Connect the 2 wires of the cable to terminals DER41÷45/48 of the PABX (FT105P or FT208P) or L+ and L- of the telephone inter- face FT11D. Apply the 4 anti-slip rubber pads in their Fix the WB700 bracket to the table adapter housings under the table adapter base.
  • Page 154 INTERNAL STATIONS PROGRAMMING The ST740W has been developed for exclusive use with Farfisa How to program the buttons PABX’s or telephone interface. It is programmed for use with FT105P and FT208P PABX by default. The default setting can be modified as The buttons can change their function by changing programming as described below in this manual.
  • Page 155 ; no tone is heard on the loudspeaker - press the button you want to program (M3, M4, M5 or M6) Note. If the telephone is connected to a Farfisa PABX's, you must dial - dial the number on the keypad (max. 24 digits) 0, 81 or 82 to access the external line.
  • Page 156 INTERNAL STATIONS VIDEO INTERCOM-TELEPHONE SET To realise a video intercom-telephone system Choosing the video connection with co- FIXING ELEMENTS for Studio se- you must combine the ST740 telephone with axial cable or twisted pair ries. bracket WB700 to a monitor ST7100 (or ST7100C) and bracket WB7100.
  • Page 157 INTERNAL STATIONS The video intercom-telephone system can be also realized by separat- ing the intercom/telephone function from the video function. For ex- ample: install the monitor on the wall and use a standard or cordless telephone to answer to intercom/telephone calls. 1 2 3 Y X P P 8 1 MONITOR ONLY...
  • Page 158 INTERNAL STATIONS Table version 5) Mark the colour/terminal combination on the junction box. 1 2 3 Y X P P 8 1 1) Apply the 4 anti-slip rubber pads in their housing under the table 6) Connect the monitor cable to the adapter base.
  • Page 159 INTERNAL STATIONS VIDEO INTERCOM-TELEPHONE SET Installation steps for monitor ST7100W (or ST7100CW), telephone 1 2 3 ST740W, brackets WB7100 and WB700 and table adapters (if neces- sary) to obtain an internal station with video intercom-telephone func- tions. Wall version " "...
  • Page 160 INTERNAL STATIONS 1 2 3 Y X P P 8 1 7) Connect the monitor cable to the bracket. 5) Hook the telephone to the bracket WB700. 1 2 3 Y X P P 8 1 8) Hook the monitor to the bracket. 6)Make the connections on the terminal board of bracket WB7100 according to the installation diagram.
  • Page 161 INTERNAL STATIONS Table version 4) Screw the 2 metallic frames to the table adapter TA7100 and hook the plastic frame to them (c). 1) Apply the 8 anti-slip rubber pads in their housings under the base of the table adapters TA7100 and TA700. 5) Screw the table adapter TA700 to the 2 metallic frames.
  • Page 162 INTERNAL STATIONS VIDEO INTERCOM-TELEPHONE WITH VIDEO MEMORY 3) Hook the monitor and telephone according to the instructions on ST7M32W. Video memory. pages 157 and 158 from point 3 to 8. For information on connections and specifications see the instructions manual supplied with the product. The only difference between video intercom and video intercom-telephone connections is represented by the fact that in video intercom-telephone systems the 4 main functions of the video memory can not be remotely actuated with the telephone...
  • Page 163 INTERNAL STATIONS Table version 4) Screw the 4 metallic frames on the table adapters and hook the 2 plastic frames to them (see drawing 4 on page 159). 1) Apply the 12 anti-slip rubber pads supplied in their housing under the base of the table adapt- ers TA7100 e TA700.
  • Page 164 INTERCOM-TELEPHONE INTERFACE " " " Telephone and electrical connections PROGRAMMING THE TELEPHONE FT11D. Intercom-telephone interface. ST740W It allows the connection of the trunk line and the - Connect the two wires of the trunk line (tele- Both a standard telephone and model ST740 intercom system to home telephone.
  • Page 165 TELEPHONE PROTECTIONS PR1. Protection for 1 telephone line. ELECTRICAL ASSEMBLING Intercom call The protection device must be connected to the PR2. Protection for 2 telephone lines. An intercom call is signalled on the telephone ground system using the terminals provided and/ PRAL.
  • Page 166 Only use the devices for the purpose it was designed for. The manu- intercommunicating service between Farfisa dedicated telephones facturer is not responsible for possible damages arising from im- (art.
  • Page 167 PABX INSTALLATION For correct operation, make sure that the openings or slots for venti- unscrew the 2 screws to remove the protection cover of the power lation and heat dissipation are not blocked. supply Install the PABX away from devices generating strong magnetic connect the 2 electrical conductors to terminals L and N fields (such as copying machines).
  • Page 168 PABX EXPANSION BOARDS ES70. Caller identifier board Installation of the ES60 (or ES65) intercom interface and ES70 caller identifier board in the FT105P or FT208P PABX. DANGER CAUTION:TO PREVENT THE G301 RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER ATTENZIONE: PER EVITARE RISCHIO DI SCOSSE ELET- TRICHE NON RIMUOVERE IL COPERCHIO...
  • Page 169 PABX INTERCOM INTERFACES PROGRAMMING The intercom board art. ES60 or ES65 can be installed in the PABX in Programming allows for personalizing the PABX according to the order to connect with the external intercom station, open the door/ user’s needs and for setting the operating mode for the each indi- automatic gate, turn ON the staircase lighting, etc.
  • Page 170 PABX ENABLING THE INTERCOM INTERFACE The called user can: press FLASH The access code for this service is - day 333310 (ST740) press - night 333312 (Standard) dial 6 - conversation with the external intercom station starts 0 the extension: - is not enabled to have conversations with the exter- nal intercom station Relay activation during conversation - is not enabled to activate relays (door-opener, stair-...
  • Page 171 PABX REMOTE ACTIVATION OF AUXILIARY RELAYS USING A CODE Operation This service only works when calling over the public line with a select the subscriber number to which the PABX is connected from an DTMF telephone. external telephone It allows the user with password to activate from long distance the 4 - Public Exchange call control tone actuator relays for auxiliary services (lights, thermostats, heating and air wait for the D.I.S.A.
  • Page 172 For installation instructions and wire cross- and art. FT11D have the same numbers as the section see page 26. terminals and the same functions as a Farfisa intercom connected in 4+1 intercom systems with one or more entrances. If the private conversation is necessary, the...
  • Page 173 INSTALLATION INSTRUCTIONS VIDEO SIGNAL DISTRIBUTION WITH TWISTED PAIR CONNECTION WITH FLOOR DISTRIBUTOR If the distance between the camera and the last video intercom in the system is lower than 200m, the connection can be made with 2x0.35mm² The video wires of each video intercom are insulated from the riser. wires (Ø=0,6mm;...
  • Page 174 EXTERNAL DOOR STATIONS VIDEO SIGNAL CONVERSION FROM COAXIAL CABLE TO BALANCED LINE The Studio video intercom line allows for the realisation of video SYSTEMS WITH CCTV CAMERAS intercom systems by simply using a twisted pair and the camera MD41D. If the system includes colour cameras or models for CCTV, you Installation must use a video converter to transform the video signal from coaxial to balanced.
  • Page 175 INSTALLATION DIAGRAMS Si 111T/1 ONE-WAY INTERCOM-TELEPHONE SYSTEM WITH TELEPHONE INTERFACE AND CONNECTION TO ONE EXTERNAL DOOR STATION Trunk line Programming When using the interface FT11D with the telephone PA = Door release button (optional) ST740 it is necessary to programme the buttons dedi- SE = Electric door lock (12Vac-1Amax.) cated to the intercom functions (see page 162).
  • Page 176 When using the telephone interface FT11D with the telephone ST740 it is PuntoVirgola, 900 and 700 can be installed. necessary to programme the buttons dedicated to the intercom functions (see ** Articles not supplied by ACI Farfisa. page 162). ) Rain shelters are used instead of back boxes and hood covers.
  • Page 177 Si 11MT/1 MIXED INTERCOM/TELEPHONE SYSTEM CONNECTED TO ONE EXTERNAL DOOR STATION Trunk line Trunk lines (MT12 - Gb2004)
  • Page 178 Si 311T/1 ONE-WAY VIDEO INTERCOM-TELEPHONE SYSTEM WITH TELEPHONE INTERFACE AND CONNECTION TO ONE EXTERNAL DOOR STATION Trunk line PA = Door release button (optional) Note Programming SE = Electric door lock (12Vac-1Amax.) For wires dimensioning and video connection When using the telephone interface FT11D refer to the installation instructions and table on with the telephone ST740 it is necessary to pages 91÷93.
  • Page 179 Si 311T/3 ONE-WAY VIDEO INTERCOM-TELEPHONE SYSTEM WITH TELEPHONE INTERFACE AND CONNECTION TO ONE EXTERNAL DOOR STATION Trunk line PA = Door release button (optional) Notes SE = Electric door lock (12Vac-1Amax.) On bracket WB7100 you must move jumper J2 from position 1-2 to 2-3.
  • Page 180 Back boxes and module frames ... Refers to number of users. * Rain shelters are used instead of back boxes and hood covers. ** Articles not supplied by ACI Farfisa. Application diagram When using MD100, MD200 amplified external door stations, place this Working instructions.
  • Page 181 Si 31MT/1 MIXED VIDEO INTERCOM / VIDEO INTERCOM-TELEPHONE SYSTEM CONNECTED TO ONE EXTERNAL DOOR STATION Trunk line Trunk lines coax (MT12 - Gb2004)
  • Page 182 Back boxes and module frames ... Refers to number of users. * Rain shelters are used instead of back boxes and hood covers. ** Articles not supplied by ACI Farfisa. Working instructions. See pages 94, 162 and 168. Notes Application diagram...
  • Page 183 Si 31MT/2 VIDEO INTERCOM-TELEPHONE SYSTEM CONNECTED TO ONE EXTERNAL DOOR STATION Trunk line Trunk lines twisted pair (MT12 - Gb2004)
  • Page 184 Back boxes and module frames ... Refers to number of users. * Rain shelters are used instead of back boxes and hood covers. ** Articles not supplied by ACI Farfisa. Working instructions. See pages 94, 162 and 168. Notes - If the maximum number of extensions is 5, you can use the PABX FT105P.
  • Page 185 Si 32MT/1 VIDEO INTERCOM-TELEPHONE SYSTEM CONNECTED TO TWO EXTERNAL DOOR STATIONS Trunk line Trunk lines twisted pair (MT12 - Gb2004)
  • Page 186 MA72 Back box and module frames WB7100 * Rain shelter is use instead of back box and hood cover. ** Articles not supplied by ACI Farfisa. Notes - If the maximum number of extensions is 5, Application diagram you can use the PABX FT105P.
  • Page 187 Si 312T/1 TWO-WAY VIDEO INTERCOM-TELEPHONE INTERCOMMUNICATING SYSTEM WITH PABX CONNECTED TO ONE EXTERNAL DOOR STATION Trunk line Trunk line coax (MT12 - Gb2004)
  • Page 188 Front frame MA72 Back box and module frames * Rain shelter is use instead of back box and hood cover. ** Articles not supplied by ACI Farfisa. Notes Application diagram - If the maximum number of extensions is 5, When using MD200 amplified external door stations, place this diagram on the diagram on page you can use the PABX FT105P.
  • Page 189 Si 312T/2 TWO-WAY VIDEO INTERCOM-TELEPHONE INTERCOMMUNICATING SYSTEM WITH PABX CONNECTED TO ONE EXTERNAL DOOR STATION Trunk line Trunk line twisted pair (MT12 - Gb2004)
  • Page 190 VIDEO INTERCOM-TELEPHONE additional diagrams Note: the extension diagrams of these 2 pages can be applied to all video intercom installation diagrams with video connection with coaxial cable. 1 PABX, 3 VIDEO INTERCOM-TELEPHONE SETS AND 5 INTERCOMMUNICATING TELEPHONES to the riser Trunk lines Note If the video system is realized with coaxial cable connected in serial...
  • Page 191 VIDEO INTERCOM-TELEPHONE additional diagrams 1 PABX, 5 VIDEO INTERCOM-TELEPHONE SETS AND 3 INTERCOMMUNICATING TELEPHONES to the riser Trunk lines Note If the video system is realized with coaxial cable connected in serial resistance R8 of the bracket WB7100 and leave it only on the last video mode (input and output from the video intercom), you must cut the 75Ω...
  • Page 192 VIDEO INTERCOM-TELEPHONE additional diagrams Note: the extension diagrams of these 2 pages can be only applied to Si311T/4, Si31MT/2 and Si32MT/1 installation diagrams (page 177, 181 and 183, respectively) because of the video connection with twisted pair. 1 PABX, 3 VIDEO INTERCOM-TELEPHONE SETS AND 5 INTERCOMMUNICATING TELEPHONES to the riser Trunk lines Note...
  • Page 193 VIDEO INTERCOM-TELEPHONE additional diagrams 1 PABX, 5 VIDEO INTERCOM-TELEPHONE SETS AND 3 INTERCOMMUNICATING TELEPHONES to the riser Trunk lines Note On bracket WB7100 you must move jumper J2 from position 1-2 to 2-3. 1 PABX, 6 VIDEO INTERCOM-TELEPHONE SETS AND 2 INTERCOMMUNICATING TELEPHONES to the riser Trunk lines Note...
  • Page 194 Module with integrated audio and with 1 button; Matrix ser. PT5160W White Flat videointercom Project series MA12P Module with integrated audio and with 2 buttons; Matrix ser. PT5160W-LCD Colour Flat videointercom Project series. White colour MA20 Blank module; Matrix series PT5660W White videointercom Project series MA22 Module with 2 call buttons;...
  • Page 195 The diagrams and information contained in this manual have been carefully verified and are to be considered as reliable. However, ACI FARFISA is not responsible for any errors, inaccuracies or infringements to patents and third-party rights that may arise from using this manual.