SERVICE MODULES
4 INPUTS AND 4 OUTPUTS LINE DISTRIBUTOR
140
/
89
5 "
1
2
/
3 "
1
2
DM2444
. In digital installations DUO the line
distributor DM2444 allows to distribute the video
signal coming from several external door
stations to the internal videointercoms
according to the addresses programmed in
the address intervals of the output lines; audio
and calling signals are on the contrary distributed
to all the devices without taking care of their
address.
Warning. The device do not allows multiple
calls and conversations. A call originated
from any external door station makes busy all
the other input and output lines until the end
of the conversation.

PROGRAMMING

Functions of LED's, buttons and micro-switches during the programming phase
LED's LI2-LI3-LI4. They point out which input
line is going to be programmed
J2-J3-J4-J5. Jumpers to be set only on the
second and additional line distributors DM2444
(if present in the installation)
J1. Connector for a system programmer
LED's LO2-LO3-LO4. They point out which
output line is going to be programmed
74
/
15
"
2
16
Technical features
Power supply from the line
Stand-by current:
Operating current:
Housing:
Operating temperature:
Maximum humidity acceptable:
Fits on DIN bar or with 2 expansion plugs
LI4
LI4
LI4
LI3
LI3
LI3
LI2
LI2
LI2
LI1
LI1
J5
J4
J3
J2
LOX
3
3
3
3
2
2
2
2
LOX
1
1
1
1
J1
LIX
LIX
LM
LM
LO4
LO4
LO4
LO3
LO3
LO3
LO2
LO2
LO2
LO1
LO1
4.
13
(MT13 - En 2015)
Terminals
LM
Power supply input
15mA
LI1 ÷ LI4
Line inputs
40mA
LO1 ÷ LO4 Line outputs
8 module A DIN
LOX (*) Connection to the output line (LO1) of
0° ÷ +50°C
a previous line distributor
90% RH
LIX (*) Connection to the input line (LI1) of a
previous line distributor
(*) Connection to be made only if more than 1
line distributor DM2444 are present in the
system (see examples on page 4.15)
SW1 - SW2. Micro-switches which allow setting
the first and last address of each address
SW2
interval
SW1
RG4
Range. Led's which point out which address
RG3
interval, among the 4 available for each line,
RG2
are going to be programmed
RG1
SKIP
SKIP Button. Allows to:
- enter the programming mode
OK
- select the programming type
- exit the programming mode
OK Button. Allows to confirm and store
programmed codes