INSTALLATION REQUIREMENTS FOR THE USER

The machine has to be placed on a stable flat
surface that can guarantee a safe position. Check
this important requirement, since the manufacturer
cannot be considered liable for any damage caused
by the instability of the appliance. While preparing
the systems, take into account that a hole is needed
in the bearing surface in order to make all electric and
water connections through the opening below where a
water softener will need to be fitted, if recommended
by the installation engineer.
A hole of 10 x 10 cm is enough in the area (a) as
indicated in Pict. 1.
The machine needs a minimum clearance of:
- height
cm. 60
- width
cm. 40
- depth
cm. 40
1
Single pole switch with an opening of at least 3 mm between
contacts
2
Water supply tap
3
Drain siphon
4
Gas supply tap (if fitted)
Between the water mains and the water inlet pipe of the appliance, there must be a tap to stop the water
flow if necessary (2 - Pict.1).
The water mains pressure must be within the range of 1 and 5 bar.
If this requirement is not met, please consult the manufacturer.
The appliance is supplied without a plug. It is supposed to be directly connected to the electric mains and
therefore, it is necessary to fit a single-pole switch with contact opening of 3 mm or more beforehand,
according to the regulations in force (1 - Pict.1).
The drainpipe of the appliance must be directly connected to a suitable open drain siphon, previously
installed by the customer (3 - Pict.1).
Do not fit the drain pipe into basins or buckets placed under the counter as this will increase the possibility
of forming dirt deposits and as a result, the spread of bacteria.
WARNING!
For appliances operating with gas, the gas supply tap must be fitted in an easily accessible place
(4 - Pict.1), so as to be able to shut off the gas supply if necessary.
Regularly check the expiry date on the gas pipe connecting the system and the appliance and have
it replaced by the Service Centre before this date.
WARNING!
The appliance is supplied without water in the boiler. This is to prevent serious damage if the
appliance is exposed to low temperatures.
The appliance must only be supplied with cold drinking water.
6
LSC 001 -UK- REV. 06
MANUAL FOR USE AND MAINTENANCE
Y
X
4
a
1
3
x
min. 20 cm.
y
min. 40 cm.
z*
min. 10 cm.
*) Distance between the back of the appliance and
the wall.
1
X
2
001