Installation Requirements For The User - La Spaziale S2 Manual For Use And Maintenance

Table of Contents

Advertisement

espresso coffee machines
• The appliance has class I protection against electric shocks.
• The noise emitted by the appliance during normal operation is less than 70 dB.
• NOTE: Appliances fitted to operate with gas system. The appliance has been fitted by the manufacturer to operate with LPG under a
maximum supply pressure of 30 mbar. Adaptation to operate with any other type of gas must be carried out by personnel authorised
by the manufacturer.
Attention!
failure to comply with the above regulations could jeopardise the correct operation and safety of the appliance as well as its
useful lifetime.

2.2 INSTALLATION REQUIREMENTS FOR THE USER

The machine has to be placed on a stable flat surface that can
guarantee a safe position. check this important requirement,
since the manufacturer cannot be considered liable for any dam-
age caused by the instability of the appliance. While preparing
the systems, take into account that a hole is needed in the bear-
ing surface in order to make all electric and water connections
through the opening below where a water softener will need to be
fitted, if recommended by the installation engineer.
A hole of 10 x 10 cm is enough in the area (a) as indicated in
pict. A.
The machine needs a minimum clearance of:
- height
cm. 60
- width
cm. 40
- depth
cm. 40
LSC 022 - Rev. 00 - Ed. 11/2011
Y
X
X
4
A
2
1
3
Fig. 4
Legend:
1 single
pole
switch
with an opening of at
least 3 mm between
contacts.
2 Water supply tap
3 Drain siphon
4 Gas supply tap (if fit-
ted)
X min. 20 cm.
y min. 40 cm.
Z* min. 10 cm.
*) Distance between the
back of the appliance
and the wall.
7