2.2

ALARMS CONTROL

RANGE NEW - EK MODEL
This model informs users as to possible malfunctions through the LEDs for the 4 preset dose buttons on
the touchpads.
1. LED CORRESPONDING TO THE COFFEE DOSE BUTTON DISPENSING, FLASHING AFTER 5-6
SECONDS:
Coffee ground too finely.
Missing reading of the pulses sent by the flow meter to the delivery group.
After checking the grinding fineness, if the problem continues, contact an authorised Service Centre.
2. ALL LEDS CORRESPONDING TO ALL DOSES ON ALL TOUCHPADS FLASHING:
The automatic refill system for the boiler has been in operation for longer than 4 minutes (total block of all machine
functions). To return to the standard operating phase, switch the machine off using the main ON/OFF switch (3). If
this problem is repeated frequently occurs, switch off the appliance and contact an authorised Service Centre.
RANGE S3 EK MODEL
This model informs users as to possible malfunctions through the LEDs on the control panel (13).
Water refill system failure (21-19 lit and 20-18 flashing)
This alarm is a blocking one and is viewed when the automatic refill system for the boiler has been
operating for longer than 4 minutes. To return to the standard operating phase, switch the appliance off
for a second using the ON/OFF switch (3); if the problem persists, switch off the appliance and contact
an authorised Service Centre.
Flow meter failure (the LED corresponding to the delivery group is flashing after 5 seconds)
This alarm is viewed when, during the delivery phase, there is a flow meter malfunction for the delivery
group, or if the coffee has been too finely ground. After checking the grinding fineness, if the problem
continues, contact an authorised Service Centre.
Transformer failure (20-18 lit and 21-19 flashing)
This alarm is a blocking one and is viewed when no power (24V) is taken on the transformer secondary,
which is feeding the solenoid valves of the groups and the automatic boiler refill. Contact an authorised
Service Centre.
Stop on P5 (LED corresponding to the dispensing unit lit)
This alarm is viewed when coffee deliveries are carried out with the manual delivery button "ON/OFF" (29) and this
has been in operation for longer than 4 minutes. To cancel the alarm, press the button "ON/OFF" (29) again.
Data loss (21-18 lit and 20-19 flashing)
This alarm is viewed when the data preset by the operator are lost and default data are reset. To cancel
the alarm, press the cup warmer operating button (24). If the problem continues, contact an authorised
Service Centre.
RANGE S5
The appliances of this range of inform users as to possible malfunctions through symbols on the control
panel and touchpads.
1. LED CORRESPONDING TO THE COFFEE DOSE BEING DELIvERED FLASHING AFTER 5-6
SECONDS (EK model only):
Coffee ground too finely.
Missing reading of the pulses sent by the flow meter to the delivery group.
After checking the grinding fineness, if the problem continues, contact an authorised Service Centre.
2. ALL DOSE SYMBOLS ON ALL TOUCHPADS FLASHING AND TEMPERATURE SYMBOLS
SWITCHED OFF:
The automatic refill system for the boiler has been operating for longer than 3 minutes (total block of all
machine operations).