Attention!
Failure to comply with the above regulations could jeopardise the correct operation and safety of the appliance as well as its
useful lifetime.
Warning!
The appliance is supplied without a plug. It is supposed to be directly connected to the electric mains and therefore, it is
necessary to fit a single-pole switch with contact opening of 3 mm or more beforehand, according to the regulations in force .

2.2 INSTALLATION REQUIREMENTS FOR THE USER

The machine has to be placed on a stable flat surface that can
guarantee a safe position. Check this important requirement,
since the manufacturer cannot be considered liable for any dam-
age caused by the instability of the appliance. While preparing
the systems, take into account that a hole is needed in the bear-
ing surface in order to make all electric and water connections
through the opening below where a water softener will need to be
fitted, if recommended by the installation engineer.
A hole of 10 x 10 cm is enough in the area (a) as indicated in
Pict. 6.
The machine needs a minimum clearance of:
- height
cm. 60
- width
cm. 40
- depth
cm. 40
12
Y
X
X
A
2
1
3
Fig. 6
espresso coffee machines
Legend:
1 Single pole switch
with an opening of at
least 3 mm between
contacts
2 Water supply tap
3 Drain siphon
X min. 20 cm.
Y min. 40 cm.
Z* min. 10 cm.
*) Distance between the
back of the appliance
and the wall.
LSC 040 - Rev. 00 - Ed. 12/2009