Installation Requirement Made By The User - La Spaziale S1 Vivaldi User Manual

Hide thumbs Also See for S1 Vivaldi:
Table of Contents

Advertisement

1.5
INSTALLATION REQUIREMENTS MADE BY THE USER
The machine needs to be placed on a stable surface which grants a safe position.
Check this important requirement, since the manufacturer cannot be considered liable for any damage
caused by the instability of the equipment.
While prearranging the system, consider the hole on the bearing surface in order to carry out all electric
and water connections through the opening below where, if recommended by the installer, the water softner
needs to be placed. A hole of 10x10 cm is enough in the area (a) indicated in PICTURE 1.
The minimum space under the machine needs to be:
- height 60 cm
- width 40 cm
- depth 40 cm
1
Main switch
2
Water supply tap
The electric plug needs to be in a position so that it can be easily reached.
Between the water mains and the water inlet pipe of the equipment, there must be a tap in order to
stop the water flowing in case of need (pict. 1).
The water mains pressure needs to be within the range 1 - 5 bar.
In case of lack of this last requirement, please consult the manufacturer.
WARNING!
The machine is supplied with no water inside the boiler to prevent serious damage if exposed to
low temperatures.
The machine must be supplied with cold, drinkable water.
6
LSC 008 -UK- REV. 04
X
1
x
min. 20 cm.
y
min. 40 cm.
z*
min. 10 cm.
*
Distance between the back side of the machine and the wall.
USE AND MAINTENANCE
Y
X
a
2
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents