Operating Components Ee245 - E+E Elektronik EE240 Operating Manual

Series ee240 wireless sensor for humidity temperature co2
Hide thumbs Also See for EE240:
Table of Contents

Advertisement

3.2.6

Operating components EE245

1. Interval rotary-switch „TIME"
2. Push-button „CONNECT"
3. Jumper „J1" (EXT/BAT)
1. Interval rotary-switch "TIME":
With the rotary switch "TIME", the following transmission and measurement intervals can be selected:
Switch positon
0
1
2
3
4
5 = default
6
7
8
9
Attention: With the webserver (EE242 Base Station), any time interval can be configured. Selecting a
time interval of less than 15 minutes for the transmitter will greatly reduce the operating life of the
batteries. Typical operating life is up to 3 years, based on a transmission interval of 15 minutes (for T /
%RH).
2. Push-button „CONNECT":
To establish the initial connection between the base station and the transmitter.
(For a detailed technical description, see chapter 4. "Starting up the Wireless System".)
Additionally the status of "signal strength level [%]" can be activated temporary with this key. If you
press the key for 1 sec while connecting the voltage supply (or the last battery is inserted) the EE244
shows the "signal strength level [%] of the wirless connection for 60 sec before switching back to the
normal display mode.
3. Jumper „J1" (EXT/BAT):
The allocation of the jumper allows for the selection of 'battery power' or 'external power'.
4. Battery compartment:
Alkaline batteries, 4 off (1.5V, AA)
Operating manual Series EE240 Wireless sensor
Interval
Switch positon
20 sec.
30 sec.
45 sec.
1 min.
2 min.
5 min.
10 min.
15 min.
20 min.
30 min.
Interval
A
45 min.
B
60 min. (1 hr)
C
90 min. (1,5 hr)
D
120 min. (2 hr)
E
180 min. (3 hr)
F
240 min. (4 hr)
4. Battery compartment
5. Humidity-Module
6. CO2-Module
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ee244Ee242Ee245

Table of Contents