C
- Pre-operation inspection
4.8 -
O
PERATING TEMPERATURE
Hydraulic energy to perform machine movements is provided by an electric motor driven
hydraulic pump.The operating speed of the pump is governed by a speed regulator. If the
temperature limits are reached, an audible alarm alerts the operator. All movements are cut
off except getting back to transport position.
Temperature limits :
• from 0° C / 32° F to + 40° C / 104° F
4.9 -
M
ACHINE BRAKING
When electric power is cut off, the machine stops automatically.
Performance levels may be reduced in the following situations :
• Descending a bumpy ramp.
• Worn tires/tyres.
• Damp or muddy ground conditions.
Check that the brakes are applied automatically when the Drive joystick is released to the
neutral position.
4.10 - W
HEEL MOTOR BRAKE RELEASE
Each time a drive command is activated, electric power releases the brakes.
4.11 - P
OTHOLE PROTECTION SYSTEM
The machine is equipped with a pothole mechanism under the chassis that is deployed
automatically when the platform is out of the stowed position.
Check the system for damage and ensure that it deploys when the platform is raised.
64
4000415480
(F
OR
L o c a t i o n o f o p e r a t i n g t e m p e r a t u r e t h e r m o s t a t
EAC
STANDARD ONLY
E 01.18
)
USA / GB