Control
Generator option (For HB135JRT only)
15 mn
Control
Generator option (For HB135JRT only)
1 - You will need
• Standard tool kit
• Multimeter
• Protective goggles
• Gloves
2 - Preliminary procedure
1.
Place the machine in maintenance configuration.
configuration
N.B.-:-The generator's performances are linked to the hydraulic oil temperature. Ensure that the
hydraulic oil temperature is between 30 °C(86 °F) and 70 °C(158 °F) during the operations.
3 - Power supply voltage control
1.
Disconnect all equipment connected to the generator (welder, hand equipment, ...).
2.
Start up the machine.
3.
Start the generator.
4.
Wait for the generator to stabilize.
5.
Measure the voltage at the welder outlet using a multimeter.
N.B.-:-The voltage between each phase must be between 210 V AC and 240 V AC.
6.
Measure the voltage at the 110 V outlet.
N.B.-:-The voltage at each outlet must be between 110 V AC and 135 V AC.
If a malfunction occurs, contact HAULOTTE Services®.
2420333140
E06.13
• Place barriers around the perimeter of the
work area
3.3.1-Placing the machine in maintenance
E041
139
EN