Mitsubishi Electric MELSEC-L SERIES Basic User Manual page 304

Melsec-l ethernet interface module
Hide thumbs Also See for MELSEC-L SERIES:
Table of Contents

Advertisement

Item
Display Format
INIT.
OPEN
ERR.
H/W LED
COM. ERR.
Information
BUF1 to
BUF16
NET NO.
GRP NO.
ST NO.
MODE
H/W SW
Information
CONFIG
302
Switches the input format of "H/W LED Information" and "H/W SW Information".
Indicates the statuses of the LEDs on the E71.
0000: Off
0001: On
Indicates the connection statuses of the connection numbers 1 to 16.
0000: Open not completed
0001: Open completed
Indicates the network No. of the E71.
Indicates the group No. of the E71.
Indicates the station number of the E71.
Indicates the mode of the E71.
0000: Online
0001: Offline
0002: Self-loopback test
0003: H/W test
Indicates the operating status of the E71, which has been set with a programming tool.
b15
1) Communication data code setting
0: Communications in a binary code
1: Communications in an ASCII code
2) Initial/open method setting
0: No parameter setting
(start up according to the sequence program)
1: Parameter setting
(start up according to the parameters)
3) TCP Existence confirmation setting
0: Use the Ping
1: Use the KeepAlive
Description
b9 b8
b7 b6
b5 b4 b3 b2 b1
1/0
1/0
1/0
1/0
6)
5)
4)
3)
4) Send frame setting
0: Ethernet frame
1: IEEE 802.3 frame
5) Setting of write enable/disable at RUN time
0: Disable
1: Enable
6) Initial timing setting
0: Do not wait for OPEN
1: Always wait for OPEN
b0
1/0
1/0
2)
1)
(Communications impossible at STOP time)
(Communication possible at STOP time)