Zp.errrd - Mitsubishi Electric MELSEC-L SERIES Basic User Manual

Melsec-l ethernet interface module
Hide thumbs Also See for MELSEC-L SERIES:
Table of Contents

Advertisement

15.12

ZP.ERRRD

This instruction reads error information stored in the buffer memory of the E71.
ZP.ERRRD
Internal device
*1
Setting data
(system, user)
Bit
(S1)
(D1)
*1
The file registers set for each local device and program cannot be used.
(1) Setting data
Setting data
Un/"Un"
(S1)
(D1)
230
Link direct device
File
register
Word
Bit
Description
Start I/O number of the E71 (00 to FE
of the three-digit I/O number)
Start number of the device that stores control data
The start number of the bit device in the own station that
turns on for one scan upon completion of the instruction.
(D1)+1 also turns on if the instruction ends abnormally.
Command
ZP.ERRRD
Available device
Intelligent
J\
function module
device U\G
Word
: The first two digits
H
Un
(S1)
(D1)
Index
Constant
register
Zn
K, H
$
Set by
Data type
BIN 16-bit/character
User
string
User, system
Device name
System
Bit
Others

Advertisement

Table of Contents
loading

Table of Contents