Differences In Functions According To The Remote Password Check Status (Enabled/Disabled) - Mitsubishi Electric MELSEC-L SERIES Basic User Manual

Melsec-l ethernet interface module
Hide thumbs Also See for MELSEC-L SERIES:
Table of Contents

Advertisement

14.4.4
Differences in functions according to the remote password
check status (enabled/disabled)
The following table lists the behavior of the functions according to the remote password check status
(enabled/disabled).
Function
Connection with MELSOFT products and a
GOT
User open port
MC protocol
communications
Auto-open UDP port
User open port
Communications
using SLMP
Auto-open UDP port
Communications using the predefined protocol
Communications using the predefined protocol
support function
Procedure exists
Communications
using a fixed buffer
No procedure
Communications using a random access buffer
E-mail function
Web function
CC-Link IE Controller Network, CC-Link IE Field
Network, MELSECNET/H, and
MELSECNET/10 relay communications
Communications using data link instructions
186
Remote password check setting
Disabled
After an initial process is completed,
communications are enabled by
establishing a connection in the
programming tool.
After an open process is completed,
communications are enabled.
After an initial process is completed,
communications are enabled.
After an open process is completed,
communications are enabled.
After an initial process is completed,
communications are enabled.
After an open process is completed,
communications are enabled.
After an initial process is completed,
communications are enabled by
establishing a connection in GX Works2.
After an open process is completed,
communications are enabled.
After an initial process is completed, data
sending and receiving are enabled.
After an initial process is completed,
communications are enabled.
Enabled
After the remote password is entered,
communications are enabled. The remote
password lock process is automatically
performed when the project is closed.
After an open process is completed,
communications are enabled from the time
that the unlock command is received until
the lock command is received.
After an initial process is completed,
communications are enabled from the time
that the unlock command is received until
the lock command is received.
Use MC protocol to communicate with the
CPU module where a remote password is
set because SLMP does not have unlock
and lock commands.
After an open process is completed,
communications are enabled.
After the remote password is entered,
communications are enabled. The remote
password lock process is automatically
performed when the protocol setting data
are closed.
After an open process is completed,
communications are enabled from the time
that the unlock command is received until
the lock command is received.
After an open process is completed,
communications are enabled.
After an open process is completed,
communications are enabled from the time
that the unlock command is received until
the lock command is received.
After an initial process is completed, data
*2
sending and receiving are enabled.
After the remote password is entered,
communications are enabled. The remote
password lock process is automatically
performed when the Web browser is
closed.
After an initial process is completed,
communications are enabled.
*1
*1
*2
*3