1. INTRODUCTION ................................................. 2
1.1 System Features .......................................... 2
Panel and Bracket Mounting ............................. 8
"K" in Figure 3.1) ................................................ 8
"B" in Figure 3.1) ................................................ 9
"L" in Figure 3.1) .............................................. 10
detail "E" in Figure 3.1) .................................... 11
3.7 Installing the PowerLink3 .......................... 12
Figure 3.1) ......................................................... 13
3.9.1 Battery Insertion ................................. 16
Panel ................................................................. 17
D-304267
PowerMaster-33 G2 Installer's Guide
PowerMaster-33 G2
Version 18
Installer's Guide

Table of Contents

4.
........................................................................... 18
4.3 Using the Prox Tag ..................................... 19
5. MAINTENANCE ................................................. 19
5.2 Replacing the Backup Battery ................... 19
5.3 Fuse Replacement ...................................... 19
5.5 Annual System Check ................................ 19
APPENDIX A. Specifications ............................... 20
A1. Functional ................................................... 20
A2. Wireless ...................................................... 20
A3. Electrical ..................................................... 20
A4. Communication .......................................... 21
A5. Physical Properties .................................... 21
Operations by KP-250 PG2 Keypad .................... 23
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PowerMaster-33 G2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Visonic PowerMaster-33 G2

  • Page 1: Table Of Contents

    4.2 Enrollment of the First KP-250 PG2 Keypad 3. POWERMASTER-33 G2 INSTALLATION ..7 ................18 3.1 PowerMaster-33 G2 Wiring Diagram ... 7 4.3 Using the Prox Tag ........19 3.2 Opening the PowerMaster-33 G2 Control 5. MAINTENANCE ..........19 Panel and Bracket Mounting ......
  • Page 2: Introduction

    The system consists of the PowerMaster-33 G2 control panel that does not include a built-in keypad and that operates in conjunction with a wireless keypad display device (KP-250 PG2). The control panel accommodates all control circuitry and operation software for a programmable 64-zone alarm system, while the keypad display unit enables the installer and the user to enter their commands and provides visual and audible feedback.
  • Page 3 / SMD-427 PG2 Installation Instructions flood. Wired Siren outputs The control panel can operate a wired siren Install and connect wired siren: see and strobe devices section 3.8 Optional Expander Module D-304267 PowerMaster-33 G2 Installer's Guide...
  • Page 4 Connect the external system output to the disarming of the PowerMaster system panel: see section 3.8 Optional Expander Module Mounting, Figure 3.8b Supported in specific PowerMaster-33 G2 variants (for further details, please contact your Visonic representative). D-304267 PowerMaster-33 G2 Installer's Guide...
  • Page 5 Smoke & Heat Temperature KP-160 PG2 Keyprox Smoke Detector Detector Detector Sirens KP-250 PG2 GSD-441 PG2 GSD-442 PG2 FLD-550 PG2 Gas (Methane) Flood Carbon Monoxide (CO) SR-730 PG2 SR-720 PG2 Detector Detector Detector Outdoor Indoor Siren Siren D-304267 PowerMaster-33 G2 Installer's Guide...
  • Page 6: Choosing The Installation Location

    It is suggested to use the DSL alarm filter model Z-A431PJ31X manufactured by Excelsus Technologies, or equivalent. This filter simply plugs into the RJ-31X jack and allows alarm reporting without breaking the internet connection. D-304267 PowerMaster-33 G2 Installer's Guide...
  • Page 7: Powermaster-33 G2 Installation

    3. POWERMASTER-33 G2 INSTALLATION Required tool: Philips screwdriver #2. PowerMaster-33 G2 mounting process is shown in Figures 3.1 - 3.10. 3.1 PowerMaster-33 G2 Wiring Diagram A. Expander Module Flat B. Wired Zone / Special C. Battery Connector D. ENROLL button...
  • Page 8: Opening The Powermaster-33 G2 Control Panel And Bracket Mounting

    3.2 Opening the PowerMaster-33 G2 Control Panel and Bracket Mounting A. Mounting surface To Mount the Unit: 1. Release the screws B. Back unit 2. Remove the front cover C. 5 screws , then 3. Mark 5 drilling points on the mounting surface...
  • Page 9: Connecting Wired Zone And Siren (Detail "B" In Figure 3.1)

    F. Magnetic contact or any other contact (not a detector) G. Alarm N.C. Figure 3.4 – Wired Zone and Siren Wiring Wired zones can be enrolled in any zone in the PowerMaster-30 G2 control panel from 01 to 64 D-304267 PowerMaster-33 G2 Installer's Guide...
  • Page 10: Gsm Module And Sim Installation (Detail "L" In Figure 3.1)

    IMPORTANT! Do not insert or remove SIM card when system is powered by AC power or backup battery. the control panel is powered by AC power or battery. Figure 3.5 – Optional GSM Module Mounting and SIM Card Insertion D-304267 PowerMaster-33 G2 Installer's Guide...
  • Page 11: Pgm-5 Installation (Located In Place Of Detail "E" In Figure 3.1)

    (for further details see the PGM-5 Installation Instructions). The PGM-5 provides 5 solid state relay contact outputs and is designed to be used as a plug-in internal add-on module with the PowerMaster-33 G2 control panel. Mount the PGM-5 module as shown in Figure 3.6.
  • Page 12: Installing The Powerlink3

    A. Cat-5 cable to home router B. Flat cable B1. This side for front unit B2. This side for PowerLink3 Figure 3.7 – PowerLink3 Mounting D-304267 PowerMaster-33 G2 Installer's Guide...
  • Page 13: Optional Expander Module (Detail "I" In Figure 3.1)

    Caution! The receptacle with strain relief clip is for the front unit – do not connect it to the back unit! A. 2 clips B. Flat cable with one strain relief clip B1. This side for front unit B2. This side for back unit Figure 3.8a –Expander Module D-304267 PowerMaster-33 G2 Installer's Guide...
  • Page 14 WARNING! When plugging terminals back into place, be sure to align them carefully with the pins on the PCB. Misaligned or reverse insertion of terminals may damage internal PowerMaster-33 G2 circuits! IMPORTANT! The terminals for internal and external sirens are DC outputs intended for 12V sirens. Connecting a loudspeaker to any of these outputs will cause a short circuit and will damage the unit.
  • Page 15: Connecting Power To The Control Panel

    (D). 4. Connect the power supply output cable (G) to the power connector (H) in the front panel. Figure 3.9a – Power Cable Clamp Extraction and Power Connection for Internal Power Supply D-304267 PowerMaster-33 G2 Installer's Guide...
  • Page 16: Battery Insertion

    Figure 3.9c – Battery Insertion 3.9.2 Connect AC Power to the Unit Connect power to the PowerMaster-33 G2 to mains power outlet (see Figures 3.8a and 3.8b). Disregard any “trouble” indications pertaining to lack of battery or lack of telephone line connection.
  • Page 17: Closing The Powermaster-33 G2 Control Panel

    3.10 Closing the PowerMaster-33 G2 Control Panel Control panel final closure is shown below. To Close the Control Panel: 1. Connect the flat cables, between front and back units, in their respective connectors (up to 3, according to options). 2. Make sure that the "Power" indicator on the control panel lights green.
  • Page 18: Visual Indications, First Keypad Enrollment And Using Prox Tag

    – see Figure 3.1) for 2 seconds. If no keypad exists in the first location, the "ENROLL" LED on the PowerMaster-33 G2 blinks slowly for 1 minute (go to step 3). If a keypad already exists in the first location, the "ENROLL" LED on the PowerMaster-33 G2 control panel lights steady for 10 seconds (go to step 2).
  • Page 19: Using The Prox Tag

    5.3 Fuse Replacement The PowerMaster-33 G2 has two internal fuses that has automatic reset. Therefore, there is no need to replace the fuses. When over current condition occurs, the fuse cuts off the circuit current. Upon fault current being removed for several seconds, the fuse is automatically reset and allows current flow through the circuit again.
  • Page 20: Appendix A. Specifications

    380 mA 70 mA 125 mA 160 mA 35 mA 70 mA 95 mA max backup w/o 12 mA 25 mA load 22 hours no backup 0 mA 10 mA no backup no backup 0 mA D-304267 PowerMaster-33 G2 Installer's Guide...
  • Page 21: A4. Communication

    Site Internal Siren Current (INT) 450* mA max @ 12.5 VDC when powered by AC/DC (10.5 VDC when in standby mode) Total PowerMaster-33 G2 output current (of INT & EXT sirens, PGM output and detectors) cannot exceed 550 mA. Current sink to control panel GND 100 mA max.
  • Page 22: Appendix B. Compliance With Standards

    APPENDIX B. Compliance with Standards Hereby, Visonic Group declares that the PowerG series of central units and accessories are designed to comply with: Compliance with  European CE Standards Standards The PowerMaster complies with the RTTE requirements - Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999.
  • Page 23: Quick User Guide To Main Alarm Control Operations By Kp-250 Pg2 Keypad

    When pressing the Fire or Emergency icons, the KP-250 ( 2 sec.) PG2 starts beeping. After pressing the button for approx. 2 Fire alarm seconds, the KP-250 PG2 sends the command. ( 2 sec.) Panic alarm ( 2 sec.) D-304267 PowerMaster-33 G2 Installer's Guide...
  • Page 24 Preparing to Arm Before arming, make sure that READY is displayed. HH:MM READY This indicates that all zones are secured and you may arm the system as desired. If at least one zone is open (disturbed) the display will read: HH:MM NOT READY This indicates that the system is not ready for arming and in most cases that one or more zones are not secured.

Table of Contents