Table 6.20
32-Bit Operating Register/SCRIPTS RAM Read
Symbol
Parameter
t
Shared signal input setup time
1
t
Shared signal input hold time
2
t
CLK to shared signal output valid
3
Figure 6.13 32-Bit Operating Register/SCRIPTS RAM Read
CLK
(Driven by System)
FRAME/
(Driven by Master)
AD
(Driven by Master-Addr;
LSI53C895A-Data)
C_BE/
(Driven by Master)
PAR
(Driven by Master-Addr;
LSI53C895A-Data)
IRDY/
(Driven by Master)
TRDY/
(Driven by LSI53C895A)
STOP/
(Driven by LSI53C895A)
DEVSEL/
(Driven by LSI53C895A)
6-18
t
1
t
2
Addr
In
t
2
t
1
CMD
t
2
t
1
In
t
2
t
1
t
3
Electrical Specifications
Byte Enable
t
3
Min
Max
7
–
0
–
–
11
t
3
Data
Out
t
2
t
3
Out
t
2
Unit
ns
ns
ns