■ Convenient/Advanced Functions
● Advance angle
compensation
function
8 output
16 output 32 output
● Bank function
16 output 32 output
● Rotational speed
alarm (upper limit/
lower limit)
function
8 output
16 output 32 output
This function advances the ON/OFF timing from the preset angle in
propor tion to the rotational speed of the machine (encoder). It
automatically compensates for the delay in output timing during high-
speed operation, eliminating the need to switch the program according
to the operation speed that is a characteristic of conventional systems.
Refer to "4.2 Advance Angle Compensation (ADV) Function".
Example
When 2° is set to the angle advancement for a rotational
speed of 100 r/min
Cam program setting
In high-speed operation
(500r/min)
The bank function allows registration of up to eight types of programs.
You can switch among them simply by selecting a desired program
when changing a setup or the targeted type of a workpiece.
The bank function also simplifies programming since it offers a
program copy function.
Refer to "4.8 Bank Function (F7/F8/F9)".
Cam Program (Bank No. 7)
Cam Program (Bank No. 2)
Cam Program (Bank No. 1)
Cam Program (Bank No. 0)
Step 0
Step 1
Cam output
(cam number)
ON angle OFF angle
ON angle
OFF angle
°
°
°
°
1
45
90
135
225
°
°
°
°
2
0
90
135
180
°
°
°
°
32
90
225
270
285
It is possible to set upper and lower limit values for the rotational
speed. When the actual rotational speed exceeds the upper-limit
value or falls below the lower-limit value, the corresponding alarm is
output.
Refer to "4.5 Speed Alarm (F3/F4)".
Rotational speed
Upper limit alarm output
Lower limit alarm output
1.2 Features
20 °
Angle advancement of 10°
10 °
40 °
Production of a wide variety
of products
Step 9
ON angle
OFF angle
°
°
270
315
°
°
315
345
50 °
Upper limit value
Lower limit value
1-5