Omron H8PS Operation Manual page 117

Cam positioner
Hide thumbs Also See for H8PS:
Table of Contents

Advertisement

Characteristics
Setting unit
Number of steps
Inputs
Encoder input
Encoder cable extension distance
Output response time
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Destruction
Vibration
resistance
Malfunction (*4)
Destruction
Shock
resistance
Malfunction (*4)
Weight
*1: Cam output precision, however, is 2° max. for Encoder with 256 resolution (P/R).
*2: All 32-output Models have a maximum of 160 steps total for all cam outputs.
*3: 1000 r/min max. when an E6CP AG5C-C Encoder is connected.
*4: Excluding USB communications.
0.5° increments at a resolution of 720, 1° increments at a resolution of
256 or 360 (*1)
Up to 10 steps can be set for each cam to turn the output ON/OFF 10
times. (*2)
Connections to a dedicated absolute encoder
• Response rotation speed (in Run/Test Mode)
1,600 r/min max. at a resolution of 256 or 360 (1,200 r/min max. if
angle advancement is set for 4 or more cams) (*3)
800 r/min max. at a resolution of 720 (600 r/min max. if angle
advancement is set for 4 or more cams)
• Includes error data detection
256/360 resolution
100 m max. at 330 r/min or less
52 m max at 331 to 1,200 r/min
(331 to 900 r/min if angle advancement is set for 4 or more cams)
12 m max. at 1,201 to 1,600 r/min
(901 to 1,200 r/min if angle advancement is set for 4 or more cams)
720 resolution
100 m max. at 330 r/min or less
52 m max at 331 to 600 r/min
(331 to 450 r/min if angle advancement is set for 4 or more cams)
12 m max. at 601 to 800 r/min
(451 to 600 r/min if angle advancement is set for 4 or more cams)
0.3 ms max.
100 MΩ min. (at 500 VDC) between current-carrying terminals and
exposed non-current-carrying metal parts, between all current-carrying
parts and the USB connector
1,000 VAC, 50/60 Hz for 1 min between current-carrying terminals and
exposed non-current-carrying metal parts
500 VAC, 50/60 Hz for 1 min between current-carrying section and USB
connector, and between current-carrying terminals and non-current-car-
rying metal part of output connector
1 kV between power terminals
1.5 kV between current-carrying terminals and exposed non-current-car-
rying metal parts
± 480 V between power terminals, ± 600 V between input terminals
Square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns
rise)
8 kV (malfunction), 15 kV (destruction)
10 to 55 Hz with 0.75-mm single amplitude each in 3 directions for 2
hours each
10 to 55 Hz with 0.5-mm single amplitude each in 3 directions for 10
minutes each
2
300 m/s
3 times each in 3 directions
2
200 m/s
3 times each in 3 directions
Approx. 300 g (Cam Positioner main unit only)
Specifications (Ratings)
A-3