<Example 2>
Limiting the number of steps to "1" for cam 3
Function setting mode
Switching to F5
Designating the cam No.
Setting the number of steps
End of setting
With the mode switch set to PRGM, hold the
[ADV] key down for at least 3 seconds to enter
the function setting mode.
PRGM
TEST
RUN
Press the [ADV] key to move to the "F5
(maximum number of steps set)" menu.
(The operation procedure up to this step is the
same as that in Example 1.)
Press the [+] or [−] key of the CAM keys to
display "3".
(In the default setting (this includes the status
after an "all clear" operation), "10" is
displayed for the step number.)
Press the [+] or [−] key of the ANGLE keys to
set "1".
"stp" starts flashing when setting starts.
Complete setting by pressing the [WRITE] key.
("stp" stops flashing and remains lit.)
4.6 Step Number Limit (F5)